1. INSTALLATION
1.1 RECEIVING
Each unit is tested and thoroughly inspected before shipment. At the time of shipment, the carrier
accepts the unit and any claim for damages must be made with the carrier. Upon receiving units
from the delivering carrier, carefully inspect carton for visible indication(s) of damage. If damage
exists, have carrier note the same on bill of lading and file a claim with the carrier.
1.2 UNPACKING
A. Cut plastic band and remove.
B. Remove top portion of carton by lifting up.
C. Remove accessory kit and loose parts from top packaging.
D. Remove top inner carton pad and corners.
E. Lift unit up by plywood shipping base, and remove lower portion of carton.
F. Inspect unit for concealed damage(s) and if evident, notify delivering carrier and file a claim
against same.
G. Remove plywood shipping base from unit by moving unit, so that one side is off the counter top
or table, allowing access to screws on the bottom of the plywood shipping base.
NOTE:
IF UNIT IS TO BE TRANSPORTED, IT IS ADVISABLE TO LEAVE UNIT SECURED TO
PLYWOOD SHIPPING BASE.
H. If unit is to be installed with optional legs, assemble legs to unit by tilting unit. DO NOT LAY UNIT
ON ITS SIDE OR BACK.
1.3 UNPACKING INSTALLATION KITS
A. Inspect kits for concealed damage and if evident, notify delivering carrier and file a claim against
same.
B. Each kit contains a list of the parts and a drawing showing the proper assembly of the parts.
1.4 SELECTING A LOCATION
A. Select a location close to a properly grounded electrical outlet and water supply that meet the
requirements as scheduled on the Specifications page.
B. Condenser air is drawn in the front of the unit and discharged out the top of the unit. A minimum
of eight (8) inches (20.3 cm) clearance must be maintained over the top of the unit.
C. Units with built-in syrup pumps must be located no more than eight (8) meters (25 feet) from
the dispensing tower, and no more than 2.4 meters (8 feet) below the tower. Use external pumps
if these limits are exceeded.
1.5 MOUNTING THE DISPENSER
A. The dispenser is designed to be permanently mounted and sealed to the counter, or installed on
four (4) inch legs.
B. When the dispenser is to be permanently bolted to the counter top, seal dispenser base to
counter top with a silicone sealant which provides a smooth and easily cleanable bond to the
counter.
C. For leg mounting, use Lancer leg kit (PN 82-0962).
NOTE:
NSF listed units must be sealed to the counter, or have four (4) legs installed.
1
!
WARNING
FAILURE TO MAINTAIN THIS CLEARANCE WILL CAUSE THE COMPRESSOR TO
OVERHEAT AND WILL RESULT IN COMPRESSOR FAILURE.