13
TROUBLE
CAUSE
REMEDY
6.21 BIB pump does not
A. Out of CO
2
, CO
2
not turned
A. Replace CO
2
supply, turn on CO
2
operate when dispensing
on, or low CO
2
pressure.
supply, or adjust CO
2
pressure to
valve is opened.
70-80 PSI.
B. Out of syrup.
B. Replace syrup supply.
C. BIB connector not tight.
C. Fasten connector tightly.
D. Kinks in syrup or gas lines.
D. Straighten or replace lines.
6.22 BIB pump operates,
A. Leak in syrup inlet or outlet
A. Replace line.
but no flow.
line.
B. Defective BIB pump check
B. Replace BIB pump.
valve.
6.23 BIB pump continues to
A. Leak in suction line.
A. Replace line.
operate when bag is
empty.
B. Leaking o-ring on pump inlet
B. Replace o-ring.
fitting.
6.24 BIB pump fails to restart A. BIB connector not on tight.
A. Tighten BIB connector.
after bag replacement.
B. BIB connector is stopped up.
B. Clean out or replace BIB connector.
C. Kinks in syrup line.
C. Straighten or replace line.
6.25 BIB pump fails to stop,
A. Leak in discharge line or
A. Repair or replace discharge line.
when dispensing valve
fittings.
is closed.
B. Empty BIB.
B. Replace BIB.
C. Air leak on inlet line or bag
C. Repair or replace.
connector.
6.26 Low or no carbonation.
A. Low or no CO
2
.
A. Check CO
2
supply. Adjust CO
2
pressure to 70 PSI.
B. Excessive water pressure.
B. Water regulator should be set at
50 PSI.
C. Worn or defective carbonator
C. Replace carbonator pump.
pump.