Summary of Contents for DELTA II 9100 Series

Page 1: ...Lancer all rights reserved Please refer to the Lancer web site www lancercorp com for information relating to Lancer Installation and Service Manuals Instruction Sheets Technical Bulletins Service Bul...

Page 2: ...TING FROM BUILT IN SYRUP PUMPS TO REMOTE PUMPS OR SYRUP TANKS 8 5 1 REMOVING EXISTING BUILT IN SYRUP PUMPS 8 5 2 INSTALLING REMOTE PUMP OR SYRUP TANKS 8 5 3 CONNECTION FOR PLAIN WATER PRODUCT 9 6 TROU...

Page 3: ...AG REPLACEMENT 13 6 25 BIB PUMP FAILS TO STOP WHEN DISPENSING VALVE IS CLOSED 13 6 26 LOW OR NO CARBONATION 13 7 ILLUSTRATIONS PARTS LISTINGS AND WIRING DIAGRAMS 14 7 1 REFRIGERATION DECK ASSEMBLY 14...

Page 4: ...e to 10 variation of the nominal line voltage consider installing a surge protector or similar protection device 4 There is a 5 minute delay which prevents the compressor and condenser fan from starti...

Page 5: ...notify delivering carrier and file a claim against same B Each kit contains a list of the parts and a drawing showing the proper assembly of the parts 1 4 SELECTING A LOCATION A Select a location clos...

Page 6: ...fan motor will not start until the 5 minute delay has elapsed 1 8 CONNECTING PYTHON TO REMOTE RECIRCULATING UNIT see Figure 1 A All remote units have the plain water feature factory installed If plain...

Page 7: ...3 Connecting Python to Remote Recirculating Unit Figure 1...

Page 8: ...2 C All Delta towers have the plain water feature factory installed If plain water is not wanted splice a stainless steel reducing barbed hose tee PN 01 0527 in the 3 8 inch soda line Use a separate...

Page 9: ...are seal washer PN 05 0017 Use a back up wrench to prevent damage to carbonator pump E Leave 1 foot 30 cm of extra tubing length below the counter for servicing and moving the dispenser F Turn on wate...

Page 10: ...syrup containers to the low pressure regulator and pressurize the containers 1 16 PURGING THE CARBONATION SYSTEM A The relief valve for the built in carbonator is located on the right hand side of th...

Page 11: ...EVERY SIX 6 MONTHS A Clean and sanitize the unit using the appropriate procedures outlined in Section 3 2 5 YEARLY A Clean water bath interior including evaporator coils and refrigeration components...

Page 12: ...IN SYRUP PUMPS TO REMOTE PUMPS OR SYRUP TANKS 5 1 REMOVING EXISTING BUILT IN SYRUP PUMPS A Disconnect the unit from the power supply and remove the bonnet B Shut off the water supply to each Valve at...

Page 13: ...ust appropriate installed o rings o rings 6 2 Insufficient water flow A Insufficient incoming supply A Verify incoming supply water water pressure pressure is a minimum of 25 PSI B Foreign debris in w...

Page 14: ...E Faulty liquid level probe E Replace liquid level probe F Water bath frozen F Thaw water bath and repair faulty component See refrigeration related symptoms G Water line frozen G Refer to Item 6 14 6...

Page 15: ...mmon and run terminal on compressor Voltage must not drop below 90 of rated voltage E PCB malfunctioning E Replace PCB assembly F Incorrect wiring F Refer to wiring diagram and correct G Faulty ice ba...

Page 16: ...water level in water bath A Add water to water bath until water normally but water line runs out of overflow into drip tray is frozen B Syrup in water bath B Drain water from water bath and refill wi...

Page 17: ...lace line operate when bag is empty B Leaking o ring on pump inlet B Replace o ring fitting 6 24 BIB pump fails to restart A BIB connector not on tight A Tighten BIB connector after bag replacement B...

Page 18: ...47 43 44 45 45 45 44 43 42 14 49 52 54 51 53 50 14 14 25 25 26 26 56 3 4 13 23 23 21 2 1 6 7 55 62 62 8 24 5 62 20 22 39 19 14 14 11 58 59 60 59 16 10 14 18 17 9 14 7 ILLUSTRATIONS PARTS LISTINGS AND...

Page 19: ...05 0502 Propeller 2 250 Dia 24 02 0040 Seal Extrusion 25 04 0032 Nut Nylok 1 4 20 26 04 0033 Washer Flat 281 ID 27 REF Compressor 83 0005 Compressor R 12 220V 50Hz Export 83 0010 Compressor R 12 220V...

Page 20: ...TO TOWER 27 14 24 5 1 3 18 2 35 10 28 15 9 25 26 6 6 30 8 31 22 20 16 12 7 17 13 6 4 29 32 33 34 21 24 19 23 7 2 CABINET ASSEMBLY 16...

Page 21: ...x 0 250 AB 17 04 0545 Screw 8 16 x 0 780 Plastite 18 06 0881 Label Key Switch 220V ONLY 19 06 0632 Label Caution Delta II Bonnet 20 06 0851 Label Overflow 21 50 0248 Insulation Front 22 82 1312 Drain...

Page 22: ...From Syrup Tubes To Compressor Deck 25 26 21 38 24 22 20 20 37 30 35 23 23 27 28 29 36 19 17 31 32 18 3 14 4 15 6 1 5 2 7 8 9 16 12 13 11 34 10 39 7 3 CARBONATOR DECK PUMP BRACKET ASSEMBLY 18...

Page 23: ...ater Fill Label 16 01 1515 Pump Outlet Assy 82 0900 Pump Bracket Assy 6 Pump 82 0906 Pump Bracket Assy 5 Pump 82 0965 Pump Bracket Assy 4 Pump 17 30 5111 Pump Support 18 04 0504 Screw 8 18 X 0 375 19...

Page 24: ...IN BOX CONFIGURATION FIGAL REMOTE CONFIGURATION 1 2 3 17 5 7 8 9 10 6 4 11 12 13 14 16 15 40 23 25 29 28 26 27 17 17 19 20 24 18 35 34 33 41 42 30 38 37 36 31 32 37 17 22 23 7 4 CARBONATOR WATER SYRUP...

Page 25: ...Tube Assy Syrup No 5 48 0477 01 Tube Assy Syrup Figal Remote Use on 6 Valve Units 48 0478 01 Tube Assy Syrup Figal Remote Use on 5 Valve Units 48 0453 01 Tube Assy Syrup Use on 6 Valve Units 48 0454...

Page 26: ...04 Lead Assy Transformer PRI 1 11 52 0905 Lead Assy Transformer PRI 2 12 52 0906 Lead Assy Compressor 1 13 52 0907 Lead Assy Compressor 2 14 52 1210 Harness Assy Recirc 15 52 0908 Harness Assy Carbona...

Page 27: ...g Barb 5 07 0481 01 Bracket Regulator 6 04 0504 Screw 8 18 x 0 375 AB 7 01 1429 Nut 7 8 18 UNS 8 07 0438 Clamp Oetiker 7 6 REGULATOR WATER ASSEMBLY 23 7 7 MERCHANDISER ASSEMBLY R TRADEMARKS RADEMARKS...

Page 28: ...BLK BLK BLK BLK BLK BLK S6 S5 S4 S3 S1 H L WHT BLK WHT OR RED WHT BLK GRN BLK GRN CAPACITOR J2 J3 J5 PCB IBC V A L V E S WIRING DIAGRAM LABEL 06 0576 03 DELTA II WHT WHT RED RED OPTIONAL WATER BOOST P...