8
Installing Remote Syrup Pumps - Bag In Box
A
B
C
A. Syrup Pump
B. CO
2
Line
C. Fitting
D. Oetiker Pliers
D
1.
Install BIB rack and remote pumps according to
manufacturers’ instructions.
2.
Once pumps and BIB rack are installed, measure and cut
tubing to length between the pump CO
2
inlets, then connect
tubing to all pumps.
3. Using tubing cutters, cut any pump CO
2
supply line and
install tee fitting, then route appropriate tubing from the CO
2
supply to the tee fitting at syrup pumps.
A
B
C
A. Syrup Pump Outlet
B. Syrup Pump
C. Fitting
4.
Cut tubing from CO
2
supply to tee fitting at syrup pumps
and install another tee fitting.
5. Attach line from carbonator CO
2
inlet to tee fitting between
syrup pumps and CO
2
supply.
A. Tee Fitting
B. Line to Syrup Pump
C. Fitting
D. Line to CO
2
Supply
A
B
B
C
D
6. Connect tubing from dispenser syrup inlet to the syrup
pump outlet fitting. Repeat for each syrup line/pump.
A
B
C
A. Tee Fitting
B. Line to Tee at Syrup Pump
C. Line to CO
2
Supply
D. Dispenser CO
2
Inlet
D
Use proper connector for syrup manufacturer
!
ATTENTION
A. Syrup Pump Inlet
B. BIB Connector
C. BIB Syrup Container
A
B
C
A. Syrup Pump Inlet C. BIB Connector
B. Fitting
D. Oetiker Pliers
A
B
C
D
7.
Install BIB (bag in box) connectors onto the syrup pump
inlet tubing.
8.
Connect syrup BIBs to connectors. Repeat for each syrup
line/pump and each flavor injector line/pump.