10
6.
For LFCV Models, connect the valve harness (PN 52-3344)
and Tower Harness (52-3732) to appropriate connections in
Junction Box.
7. For Volumetric Valve Models, Connect the VV KIP Solenoid
Harness (PN 52-3359), the VV Solenoid Harness (PN 52-
3360), VV Water Harness (PN 52-3361), and VV Ribbon
Cable (PN 52-3346) to their appropriate connections on
Main Board in Junction Box.
A
B
D
E
C
A. VV Ribbon Cable (52-3346)
B. Power Harness (52-3348)
C. LFCV Valve Harness (52-3344)
- VV KIP Solenoid Harness (52- 3359)
D. VV Solenoid Harness Conn. (52-3360)
E. Tower Harness (52-3732)
- VV Water Harness Conn. (52-3361)
Junction Box Installation
Tower harnesses and syrup/water lines are all 36
inches in length. Placement of the Junction Box must
be under the counter and within 2 feet (24 inches) of
the Tower assembly.
See image below or Wiring Diagram located in
Junction Box or on pages 27 and 28 of this manual for
reference.
NOTE
NOTE
1. Position the Mounting Bracket of the Junction Box so that
there is adequate slack for connection lines to accommo
-
date sliding the Junction Box forward for service.
2. Secure the Mounting Bracket to bottom of the counter with
four screws provided.
A
A
B
B
C
A. Mounting Bracket
B. Screws (4)
C. Bottom of Counter
A. Mounting Bracket
Secured to Counter
B. Junction Box
3. Align the Junction Box with the Mounting Bracket, then slide
box through bracket to secure to counter.
DO NOT install or set junction box on the ground, this
is a shock hazard.
!
WARNING
4. If applicable, connect the ADA harness (PN 52-3734),
routed from ADA panel in drip tray, to extra connecting
wire in Tower harness (PN 52-3732).
5. Connect the power harness (PN 52-3348) to its appropriate
connections on the main board in the junction box.