2
C. Route the drain tube to a suitable drain and replace the unit’s drip tray.
1.7
FILLING UNIT WITH WATER
A. Remove the bonnet from the unit.
B. Remove the plastic plug (located on the front of the unit’s compressor deck) from the unit’s fill
hole.
CAUTION
THE WATER BATH COMPARTMENT MUST BE FILLED WITH WATER BEFORE PLUGGING IN
THE UNIT, OTHERWISE THE COMPRESSOR DECK AND CONDENSER FAN MAY NOT
OPERATE PROPERLY.
C. Using a funnel or tube, fill the water bath compartment with water until it flows out of the
overflow tube into the drip tray.
NOTE
Do NOT use distilled water to fill water bath.
D. Replace the plug.
1.8
CONNECTING TO ELECTRICAL POWER
WARNING
THIS UNIT MUST BE PROPERLY ELECTRICALLY GROUNDED TO AVOID POSSIBLE FATAL
ELECTRICAL SHOCK OR SERIOUS INJURY TO THE OPERATOR. THE POWER CORD IS
PROVIDED WITH A THREE PRONG GROUNDED PLUG. IF A THREE-HOLE GROUNDED
ELECTRICAL OUTLET IS NOT AVAILABLE, USE AN APPROVED METHOD TO GROUND THE
UNIT.
CAUTION
FAILURE TO DISCONNECT THE MOTOR POWER SUPPLY WILL DAMAGE THE CARBONATOR
MOTOR AND PUMP AND VOID THE WARRANTY.
A. If the unit is equipped with a built-in carbonator, disconnect the power supply to the carbonator
motor by disconnecting the four pin connector located near the top of the electrical control box
on the refrigeration deck.
B. Check the dispenser serial number plate for unit’s correct electrical requirements.
Do not plug
into wall electrical outlet unless serial number plate current shown agrees with local current
available.
C. Route the power supply cord to a grounded electrical outlet of the proper voltage and amperage
rating, and plug in the unit. This will turn on the refrigeration system and allow it to start cooling
while completing the rest of the installation. The agitator motor will start immediately, but the
compressor and fan motor will not start until the five (5) minute delay has elapsed.
1.9
CONNECTING TO WATER SUPPLY
CAUTION
IF WATER SOURCE EXCEEDS 50 PSIG (3.52 KG/CM
2
) A WATER REGULATOR KIT MUST BE
USED TO LIMIT WATER PRESSURE TO 50 PSIG (3.52 KG/CM
2
). FAILURE TO USE
REGULATOR WILL RESULT IN IMPROPER PERFORMANCE OF DISPENSER.
A. Using tubing and fittings from installation kit, connect tubing assembly to water source.
DO NOT
CONNECT TO DISPENSER AT THIS TIME.
B. Flush water supply line thoroughly.
NOTE
If the water source is above 50 PSIG (3.52 KG/cm
2
), cut tubing assembly and install Water
Regulator Kit (PN 18–0253/01) as shown in kit instruction sheet.
C. Route through hole in counter and through opening behind splash plate and connect to
carbonator pump using a flare seal washer (PN 05-0017). Use a back-up wrench to prevent
damage to carbonator pump.
D. Leave 12 inches (30 cm) of extra tubing length below the counter for servicing and moving the