(Section 4.18 continued from previous page)
C. Refrigeration system not
C. Refer to Sections 4.11 - 4.15.
running.
D. Refrigerant leak.
D. Repair and recharge.
E. Condenser fan motor not
E. Replace condenser fan motor.
working.
F. Dirty condenser.
F. Clean condenser.
G. Dispenser capacity exceeded. G. Add pre-chiller.
5. ILLUSTRATIONS, PARTS LISTINGS, AND WIRING DIAGRAMS
5.1
500 CED WIRING DIAGRAM, 220-240V/50-60HZ,
LANCER ELECTRONIC ICE BANK CONTROL (INTERNATIONAL ONLY)
TROUBLE
CAUSE
REMEDY
7
WHEN STARTING UNIT OR IF CURRENT IS INTERRUPTED, THERE IS
A FIVE (5) MINUTE DELAY BEFORE THE COMPRESSOR/FAN STARTS.
IMPORTANT
06-2093 USED ON PN 82-2665 (230V/50HZ) AND PN 82-2666 (240V/60HZ)
GREEN
BLACK
WHITE
JCT
220-240V /
50-60HZ AC
FAN
MOTOR
COMPRESSOR
OVERLOAD
C
S
M
M
L
S
RELAY
PROBE
LABEL, WIRING, 500,
REDUNDANT CONTROL
06-2093
LANCER
ICE
BANK
CONTROL
TRANSFORMER
24V LEADS
AGITATOR
MOTOR
Summary of Contents for 500 Series
Page 14: ...13 NOTES...