1.2
UNPACKING
A. Remove cup rest by lifting out.
B. Remove splash plate by pulling forward at the bottom. Drip tray can be removed before
removing splash plate.
C. Remove drip tray by lifting out.
D. Remove shipping base.
DO NOT LAY UNIT ON ITS SIDE OR BACK. DO NOT USE DRIP
TRAY FRAME FOR A HANDLE.
NOTE
If unit is to be transported, it is advisable to leave unit secured to plywood shipping base.
E. Inspect unit for concealed damage. If damage exists, notify delivering carrier note and file a
claim against the carrier.
1.3
INSTALLATION
The dispenser is designed to sit on a flat, supported surface
capable of supporting a minimum
weight of 200 pounds (90.7 kg)
. It may be either counter or leg mounted. When the dispenser is to
be permanently bolted to the counter top, seal dispenser base to counter top with a silicone sealant
which provides a smooth and easily cleanable bond to the counter.
NOTE
NSF listed units must be sealed to the counter or have four (4) inch legs installed.
WARNING
FAILURE TO MAINTAIN PROPER AIR CLEARANCE WILL CAUSE THE COMPRESSOR TO
OVERHEAT AND WILL RESULT IN PREMATURE COMPONENT FAILURE.
Locate dispenser to allow approximately 15 inches (380 mm) of unobstructed space above and six
(6) inches (152 mm) of unobstructed space in back of the unit for proper air circulation and removal
of bonnet. Air is drawn in through the back grill and is exhausted out the top grill.
A. Position dispenser on counter.
B. Remove bonnet from the dispenser.
C. Remove insulation strip from in front of refrigeration deck. Fill tank with water until water comes
out of overflow tube. Replace insulation. Use bottled water where a water problem exists.
1.4
CONNECTING TO ELECTRICAL POWER
WARNING
THIS UNIT MUST BE PROPERLY ELECTRICALLY GROUNDED TO AVOID POSSIBLE FATAL
ELECTRICAL SHOCK OR SERIOUS INJURY TO THE OPERATOR. THE POWER CORD IS
PROVIDED WITH A THREE PRONG GROUNDED PLUG. IF A THREE-HOLE GROUNDED
ELECTRICAL OUTLET IS NOT AVAILABLE, USE AN APPROVED METHOD TO GROUND THE
UNIT.
DO NOT USE EXTENSION CORDS WITH THIS UNIT. DO NOT “GANG” TOGETHER WITH
OTHER ELECTRICAL DEVICES ON THE SAME OUTLET.
A. Check the dispenser serial number plate for unit's correct electrical requirements. Do not plug
into electrical outlet unless unit electrical configuration, located on serial plate, agrees with local
available power supply.
B. Route the power supply cord to a grounded electrical outlet of the proper voltage and amperage
rating, and plug in the unit. This will turn on the refrigeration system and allow it to start cooling
and allow ice bank to form while completing installation. Approximately four (4) hours are
required to form a full ice bank.
NOTE
Units equipped with an electronic ice bank control contain a five (5) minute delay. Compressor
and fan motor will not begin running until five (5) minutes after the unit is energized.
1.5
CONNECTING SUPPLY LINES TO SOURCES
A. Connect free end of plain water lines to water supply
[must be 35 PSI (2.4 BAR) or more]
.