WARNING/ADVERTENCIA/AVERTISSEMENT

This unit is not a toy. Children should be advised not to play with appliance. It should not be used by children or 

infirm persons without supervision. This appliance is not intended for use by persons (including children) with reduced 

physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given 

supervision or instruction concerning use of the appliance by a person responsible for their safety. Cleaning and user 

maintenance shall not be performed by children without supervision. This unit is not designed to dispense dairy 

products. The min/max ambient operating temperature for the dispenser is 35°F to 75°F (1.67°C to 23.89°C). Do 

not operate unit below minimum ambient operation conditions. Should freezing occur, cease operation of the unit 

and contact authorized service technician. Service, cleaning and sanitizing should be accomplished only by trained 

personnel. Applicable safety precautions must be observed. Instruction warnings on the product being used must be 

followed.

Esta unidad no es un juguete. Los niños deben ser supervisados para no jugar con aparato. No la deben usar 

niños ni personas discapacitadas sin supervisión. Esta unidad no está destinada al uso por parte de personas 

(incluso niños) con capacidad física, sensorial o mental reducida, o sin experiencia y conocimientos suficientes, a 

menos que una persona responsable de su seguridad les haya dado supervisión o capacitación en el uso de la 

unidad. Limpieza y mantenimiento de usuario no deberá ser realizada por los niños sin supervisión. Esta unidad no 

ha sido diseñada para suministrar productos lácteos. La temperatura ambiente operativa mínima / máxima para el 

dispensador es de 35°F a 75°F (1.67°C a 23.89°C). No opere la unidad debajo de las condiciones de funcionamiento 

ambientales mínimos. En caso de congelación se produce, cesar la operación de la unidad y el contacto técnico de 

servicio autorizado. Servicio de limpieza y desinfección deben llevarse a cabo solamente por personal capacitado. 

Es necesario tomar medidas de seguridad aplicables. Advertencias de las instrucciones sobre el producto utilizado 

se deben seguir.

Cet appareil n’est pas un jouet. Les enfants doivent être surveillés afin de ne pas jouer avec l’appareil. Il ne 

devrait pas être utilisé par des enfants ou des personnes infirmes sans surveillance. Cet appareil n’est pas destiné 

à un usage par des personnes (y compris les enfants) ayant des capacités physiques, sensorielles ou mentales 

réduites, ou manquant d’expérience et de connaissances, à moins qu’elles obtiennent de la surveillance ou des 

instructions au sujet de l’utilisation de l’appareil de la part d’une personne chargée de leur sécurité. Nettoyage et 

entretien de l’utilisateur ne doivent pas être effectués par des enfants sans surveillance. Cet appareil n’est pas conçu 

pour distribuer des produits laitiers. La température de service ambiante minimum/maximum pour le distributeur est 

de 35°F à 75°F (1.67°C à 23.89°C). Ne pas utiliser l’appareil dans des conditions de performance environnementale 

minimale. En cas de gel, cesser l’exploitation de l’unité et contactez un technicien agréé. Nettoyage et désinfection 

doivent être effectuées uniquement par du personnel qualifié. Vous devez prendre des mesures de sécurité. 

Avertissements instructions sur le produit utilisé doivent être respectées.

!

!

1. INSTALLATION

 

1.1  UNPACKING THE DISPENSER

 

 

A.  Cut band and remove.

 

 

B.  Inspect unit for concealed damage. If evident, notify delivering carrier and file a claim against  

 same.

 

 

C.  Remove plywood shipping base from unit.

    

NOTE:

 If unit is to be transported, it is advisable to leave the unit secured to the plywood base.

 

 

D.  If leg kit has been provided, assemble legs to unit by tilting unit. 

DO NOT LAY UNIT ON ITS  

 

SIDE OR BACK.

 

1.2  DRAIN SPIDER

  

The drain spider is located to the left side near the front of the bin. The 

coldplate has a cavity designed to hold the drain spider. During shipment or 

installation, the drain spider may become dislodged from its original position.

Prior to installing the dispenser, ensure the drain spider is in the correct 

 

 

position.This will prevent drain clog issues. Inspect the lower bin area to 

ensure the drain spider is secure in the coldplate cutout. If the drain spider 

is not in place, locate the drain spider and reinstall in the cold plate cavity 

where drain line exists. 

Summary of Contents for 28-0940

Page 1: ...al PN 28 0940 Lancer is the registered trademark of Lancer 2014 by Lancer all rights reserved CP 09 Please refer to the Lancer Corp website lancercorp com for information relating to Lancer Installation Operation Manuals Installation Guides Instruction Sheets and Technical Bulletins or for your convenience scan this QR code with a mobile device app required for immediate access to other Technical ...

Page 2: ... must be carried out by qualified personnel with up to date safety and hygiene knowledge and practical experience in accordance with current regulations TABLE OF CONTENTS SPECIFICATIONS 3 PRE INTALLATION CHECKLIST 4 WARNINGS CAUTIONS 5 1 INSTALLATION 5 1 1 UNPACKING THE DISPENSER 5 1 2 DRAIN SPIDER 5 1 3 SELECTING COUNTER LOCATION 6 1 4 LEVELING THE DISPENSER 6 1 5 INSTALLATION OF THE UNIT 6 2 REC...

Page 3: ...inches 293 87 mm Depth 19 77 inches 502 17 mm Height 15 54 inches 394 71 mm Depth w Dip Tray 24 87 inches 631 70 mm WEIGHT Shipping 55 lbs 24 95 kg Empty 50 lbs 22 68 kg ICE Capacity 19 4 lbs 8 8 kg PRODUCT SUPPLY Minimum pressure 42 PSI 0 289 MPA Maximum pressure 46 PSI 0 317 MPA FITTINGS Product inlet 5 16 barb ...

Page 4: ...aim with carrier Responsibility for damage to the dispenser lies with the carrier Your Service Agent __________________________________ Service Agent Telephone Number ______________________ Serial Number _______________________________________ Installation Date _____________________________________ TOOLS REQUIRED Oetiker Pliers Tubing Cutters Faucet Wrench CONSIDER THE FOLLOWING PRIOR TO INSTALL D...

Page 5: ... aplicables Advertencias de las instrucciones sobre el producto utilizado se deben seguir Cet appareil n est pas un jouet Les enfants doivent être surveillés afin de ne pas jouer avec l appareil Il ne devrait pas être utilisé par des enfants ou des personnes infirmes sans surveillance Cet appareil n est pas destiné à un usage par des personnes y compris les enfants ayant des capacités physiques se...

Page 6: ...upler using 3 8 inch barb fitting D Attach keg coupler on to the keg by turing clockwise until it stops Check for leaks E Install the ice bin drain hose connect the 90 elbow or straight fitting underneath the unit s base The ice bin drain is located towards the front of the bin and slightly to the left Connect the hose Extend the hose to an open type drain F Drain line must be insulated with a clo...

Page 7: ...GRÉS F 60 DEGRÉS C CECI PEUT ENDOMMAGER LE DISTRIBUTEUR 3 CLEANING AND SANITIZING INSTRUCTIONS 3 1 GENERAL INFORMATION A The cleaning and sanitizing procedures provided pertain to the Lancer equipment identified by this manual If other equipment is being cleaned follow the guidelines established by the manufacturer for that equipment B Lancer equipment new or reconditioned is shipped from the fact...

Page 8: ...al regulations regarding disposal of the insulation 3 4 DAILY CLEANING A Using the cleaning solution clean Top Cover and all exterior stainless steel surfaces B Clean exterior of dispensing valves C Remove Drip Tray by lifting to release its mounting holes from the mounting screws D Dump water and beer and wash the Drip Tray and Splash Plate with cleaning solution E Lift the Drip Tray to hook the ...

Page 9: ... 1 EXPLODED VIEW 1 3 2 4 5 Item Part No Description 1 30 11859 Cup Rest Breeze Beer 2 01 2976 Elbow Connector JG 3 8 X5 16 3 05 3266 Drip Tray Breeze Beer 4 04 1682 2 Screw M4 0 7X4 5 4 5 Shoulder FHD PH SS 5 30 11833 Lid Metal Breeze Beer ...

Page 10: ...NOTES 10 ...

Page 11: ...INTENTIONALLY LEFT BLANK 11 ...

Page 12: ...Lancer Corp 800 729 1500 Technical Support Warranty 800 729 1550 custserv lancercorp com lancercorp com ...

Reviews: