PAGE 7
INPUT POWER REQUIREMENTS:
Operating Voltage: 12VDC via 120/240VAC 50/60Hz switching power supply
Power Consumption: 600mA @ 12VDC (7.2 watts) nominal
Size (L x W x H): 6.8” x 4.4” x 5.4”
Shipping Weight: 2 lbs.
Ozone Output: 220 mg/hr.
Enclosure: ABS
specifications
CD CELL REPLACEMENT
*CAUTION: UNPLUG POWER SUPPLY TO EOG BEFORE PERFORMING SERVICE*
1. With the front cover removed, remove the CD cell from the ozone generator:
a. Disconnect the red spade terminal connector from the CD cell connection terminal.
b. Cut the CD cell retaining strap holding the cell into the cell clips, and discard.
c. Disconnect the air inlet and ozone outlet hoses from the CD cell barb fittings.
d. Pull the CD cell straight up from the retaining clips.
2. Replace with new CD cell in reverse order, making sure all air and electrical connections are secure.
component replacement