Lancaster EOG Installation And Service Manual Download Page 1

PAGE 1

Congratulations on purchasing your new Lancaster Water Filter. This unit is designed to give you many years of trouble free 
service. For servicing and future inspection purposes, please file this booklet with your important documents.
In the event that you need assistance for servicing your water filter, please first contact the professional contractor who 
installed the system.

ENHANCED OXIDATION GENERATOR

INSTALLATION AND SERVICE MANUAL

EOG

Summary of Contents for EOG

Page 1: ...le free service For servicing and future inspection purposes please file this booklet with your important documents In the event that you need assistance for servicing your water filter please first contact the professional contractor who installed the system ENHANCED OXIDATION GENERATOR INSTALLATION AND SERVICE MANUAL EOG ...

Page 2: ...amages or injuries incurred by misuse of this product EXTERNAL It is most important to choose a cool clean external operating environment Consideration of these factors should be a priority Mount your ozone generator in the best possible operating environment that is available at the chosen site If possible mount in an area that is free of airborne moisture particles INTERNAL Keep the inside of th...

Page 3: ... valve Remove the front valve cover from backplate Release the control board bracket from backplate 3 Route the grey control wire from the EOG into valve housing through the hole in the backplate and through the strain relief channel above to keep wiring in place a Leave enough wire length to connect to the signal relay terminal block of the control circuit board Make sure the wire is flush in the...

Page 4: ...d clean CD cell then reset timer by pressing red alarm reset button on PCB once Control Input The EOG PCB is activated to produce ozone when a pilot input signal is applied across pilot terminals Auxiliary Output Functions The NO NC auxiliary outputs have a 3 second off delay after the pilot signal is shut off These outputs are capable of outputting a maximum of 60mA 70 F and are intended to be us...

Page 5: ... cell clips and discard c Disconnect the air inlet and ozone outlet hoses from the CD cell barb fittings d Pull the CD cell straight up from the retaining clips 2 Flush the CD cell with warm water until the water comes out entirely clean a Connect a 3 16 I D piece of tubing to either of the CD cell barb fittings b Using a syringe or rubber bulb pump to work the warm water through the CD cell flush...

Page 6: ...sories 33218 R EOGandOzotechEOGReplacementCDCell Keepaclean spareOzotechCoronaDischargecellonhandforeasyscheduledmainte nance Fitsthe31504andthe31506seriesEOGandOzotechEOG Part Number Description 47044 1 CD Cell Cleaning Kit CD cells within Ozotech products are designed for easy cleaning Periodic cleaning of the CD cell is important and will keep your generator operating effectively and efficientl...

Page 7: ...ERFORMING SERVICE 1 With the front cover removed remove the CD cell from the ozone generator a Disconnect the red spade terminal connector from the CD cell connection terminal b Cut the CD cell retaining strap holding the cell into the cell clips and discard c Disconnect the air inlet and ozone outlet hoses from the CD cell barb fittings d Pull the CD cell straight up from the retaining clips 2 Re...

Page 8: ...o pg 7 to ensure that unit is plugged into proper voltage outlet Unit turns on but no ozone output Frequency driver is defective Replace PCB board Frequency driver high voltage lead not connected to ozone cell Connect red flag terminal to CD cell spade connection Water has been allowed to back up into the CD cell and has caused a direct short Dry CD cell using drying procedure on pg 5 Replace CD c...