background image

PAGE 3

INSTALLATION

Place filter in desired location close to water supply inlet, after 

pressure tank, and near a source for waste water, (utility sink, floor 

drain or sewer line). A 115/120V, 60Hz uninterrupted outlet is required. 

Keep filter far enough away from walls and other obstructions to allow 

enough room for servicing the unit. If a water softener is also to be 

installed, generally it will be placed in line after the neutralizer or filter. 

From water supply→ neutralizer → filter → softener → to service

ADD MINERALS:

Remove control valve from mineral tank by turning counter-clockwise. Plug open end (top) of distributor tube assembly to 

prevent  mineral from entering 

(Fig. A)

. Add Mineral. 

DO NOT OVERFILL

. There must be at least 16” of space between 

the top of the tank and mineral 

(Fig. B)

. Remove plug from the top of the distributor tube.

Install control valve making sure the distributor tube is slipped into the center hole on the bottom of the control valve. Pipe 

filter into service line. Use of a bypass valve is recommended. Arrows are molded into valve and bypass valve to show 

direction of flow.

Click to buy NOW!

PD

F-XCHANGE

w

ww

.docu-track.c

om

Click to buy NOW!

PD

F-XCHANGE

w

ww

.docu-track.c

om

OPTIONAL BYPASS VALVE:

 The bypass valve easily connects to the control valve body using nuts that only require 

hand tightening. Install with red knobs in the upward position. Press end of bypass valve with o-rings into valve. Hand 

tighten nuts. Place into  

BYPASS OPERATION (Fig. 4)

.

Avoid getting primer and solvent cement on any part of the o-rings or split rings, bypass valve or control valve.

 DO NOT

 

use pipe dope or any other sealant on threads. Teflon tape is not necessary on the caps because of o-ring seals. 

DO 

NOT

 use Vaseline or other unacceptable lubricants on o-rings. A silicone lubricant may be used on black o-rings.

DRAIN LINE:

 The 3/4” drain line elbow accommodates 5/8” poly tube or 3/4” NPT drain line connections. The nut and 

poly tube insert for the 3/4” drain line elbow is designed for use with flexible, 

semi-rigid poly tube only. The drain line elbow can be rotated so the outlet can 

be oriented toward the nearest drain.

TO INSTALL 5/8” POLY TUBE DRAIN LINE:

 The poly tube insert is shipped 

attached to the drain line elbow’s locking clip. Press the insert into the drain line 

(5/8” poly tube not included). Loosen nut of the drain line elbow. Press 5/8” poly 

tube with insert into the drain line elbow until it seats on the back of the fitting. 

Tighten nut.
The drain line must be piped to an open drain with air gap between the drain 

and the sewer lines (Fig. 3). Under no circumstances should there be a direct 

connection with sanitary sewage facilities. If it is necessary to run the drain pipe 

overhead, (not to exceed 5’ above valve) be sure to increase the pipe size and 

follow all plumbing procedures to hold friction and restrictions to a minimum.

FIGURE 4

SERVICE

FROM WELL PUMP

PRESSURE

TANK

IN

OUT

DRAIN

LINE

BYPASS SHOULD

BE PIPED IN IF

OPTIONAL BYPASS

VALVE IS NOT USED

TO 115V

RECEPTACLE

TOP VIEW

VALVES

BRINE

LINE

Click to buy NOW!

PD

F-XCHANGE

w

ww

.docu-track.c

om

Click to buy NOW!

PD

F-XCHANGE

w

ww

.docu-track.c

om

1

2

3

Summary of Contents for 7-LETCT-1

Page 1: ...ice For servicing and future inspection purposes please file this booklet with your important documents ELECTRONIC WATER FILTER TIME CLOCK MODEL FEATURING THE 2002F VALVE INSTALLATION OPERATING AND SERVICE MANUAL COLOR TASTE ODOR 7 LETCT 1 7 LETCTG 1 7 LETCT 2 7 LETCTG 2 7 LETCT 3 7 LETCTG 3 IRON FILTER 7 LETIM 1 7 LETIMG 1 7 LETIM 2 7 LETIMG 2 7 LETIM 3 7 LETIMG 3 SEDIMENT TURBIDITY 7 LETST 1 7 L...

Page 2: ... or length in excess of 20 require 3 4 drain line Solder joints near the drain must be done prior to connecting the drain line flow control fitting Leave at least 6 between the drain line control and fitting solder joints when soldering pipes that are connected on the drain line control fitting Failure to do this could cause interior damage to the drain line flow control fitting When assembling th...

Page 3: ...nuts Place into BYPASS OPERATION Fig 4 Avoid getting primer and solvent cement on any part of the o rings or split rings bypass valve or control valve DO NOT use pipe dope or any other sealant on threads Teflon tape is not necessary on the caps because of o ring seals DO NOT use Vaseline or other unacceptable lubricants on o rings A silicone lubricant may be used on black o rings DRAIN LINE The 3 ...

Page 4: ...etween Regeneration Option STEP 1ID From normal mode press SET buttons simultaneously for 3 seconds and release Installer Displays Settings 7 Day Option STEP 1I7 From normal mode press SET simultaneously for 3 seconds and release STEP 4ID Days to Regen Set the number of days between regenerations The allowable range is 1 to 99 Press SET to exit Installer Displays and Settings STEP 2ID Regeneration...

Page 5: ...oval of chlorine color taste odor and low levels of sulfur etc The mineral bed should be backwashed periodically but will in time reach the maximum absorbency When this occurs the carbon should be completely replaced SEDIMENT AND TURBIDITY 7 LETST Mineral used Filter AG This filter will filter out dirt silica etc down to the 20 40 micron range In most cases it has a lifetime fill and should be bac...

Page 6: ... drive assembly must be removed to access the drive cap assembly The drive cap assembly must be removed to access the piston s The drive cap assembly is threaded into the control valve body and seals the o ring To remove the drive cap assembly use the optional maintenance wrench or insert a to flat bladed screwdriver into one the slots around the top 2 of the drive cap as sembly so it engages the ...

Page 7: ...nerant is used Sharp objects which can score the plastic should not be used to clean the injector Scoring the injector or increasing the diameter of the hole could change the operating parameters of the injector Two holes are labeled DN and UP For down flow systems the appropriate injector is located in the DN hole a plug is in the UP hole Push the plug and injector firmly in place replace the scr...

Page 8: ...ow handles be sure that 1 O rings on both rotors face to the right when being viewed from the front of the control valve when the handle pointers are lined up with the control valve body arrows or 2 Arrows point toward each other in the bypass position Since the handles can be pulled off they could be accidentally reinstalled 180 from their correct orientation To install the red handles correctly ...

Page 9: ...Male NPT Elbow Item No Quantity Part No Description 1 2 V3151 Nut 1 Quick Connect 2 2 V3150 Split Ring 3 2 V3105 O Ring 215 4 2 V3145 Bypass 1 Rotor 5 2 V3146 Bypass Cap 6 2 V3147 Bypass Handle 7 2 V3148 Bypass Rotor Seal Retainer 8 2 V3152 O Ring 135 9 2 V3155 O Ring 112 10 2 V3156 O Ring 214 V3007 02 1 Brass Sweat Assembly Optional V3007 03 3 4 Brass Sweat Assembly Optional V3007 1 PVC Male NPT ...

Page 10: ... 1 V3152 O Ring 135 3 1 V3177 Injector Screen 4 1 V3010 1Z Injector Assy Z Plug NOT SHOWN V3170 O Ring 011 NOT SHOWN V3171 O Ring 013 Injector plug and injector contains one 011 and one 013 O ring DRIVE CAP ASSEMBLY DOWN FLOW PISTON REGENERANT PISTON AND SPACER STACK ASSEMBLY Item No Quantity Part No Description 1 1 V3005 Spacer Stack Assembly 2 1 V3004 Drive Cap Assembly 3 1 V3135 O Ring 228 4 1 ...

Page 11: ...1 Drain Elbow and Retainer Asy DRAIN LINE 3 4 Item no Quantity Part No Description 1 1 H4615 Elbow Locking Clip 2 1 V3194 Polytube Insert 5 8 3 1 V3192 Nut for 3 4 Drain Elbow 4 1 V3158 3 4 Drain Elbow 5 1 V3163 O Ring 019 6 1 V3159 DLFC Retainer 7 1 V3162 056 DLFC 5 3 7 1 V3162 065 DLFC 6 5 7 1 V3162 090 DLFC 9 0 7 1 V3162 100 DLFC 10 0 3 4 5 1 2 6 ATER METER SHOULD NOT BE USED AS THE PRIMARY MON...

Page 12: ...not inserted fully to engage pinion motor wires broken or disconnected motor failure e Check motor and wiring Replace motor if necessary f Drive gear label dirty or damaged missing or broken gear f Replace or clean drive gear g Drive bracket incorrectly aligned to back plate g Reset drive bracket properly h PC board is damaged or defective h Replace PC board i PC board incorrectly aligned to drive...