PAGE 5
NORMAL OPERATION
BYPASS OPERATION
DIAGNOSTIC MODE
IN
OUT
IN
OUT
IN
OUT
INLET VALVE
OPEN
OUTLET VALVE
OPEN
BYPASS VALVE
CLOSED
INLET VALVE
CLOSED
OUTLET VALVE
CLOSED
BYPASS VALVE
OPEN
INLET VALVE
OPEN
OUTLET VALVE
CLOSED
BYPASS VALVE
OPEN
Click to buy NOW!
PD
F-XCHANGE
w
ww
.docu-track.c
om
Click to buy NOW!
PD
F-XCHANGE
w
ww
.docu-track.c
om
BYPASS VALVE
Normal Operation:
Water flows through the control valve during service and also allows the control valve to isolate the
media bed during the regeneration cycle.
Bypass Operation:
The control valve is isolated from the water pressure contained in the plumbing system. Untreated
water is supplied to the plumbing system.
Diagnostic Operation:
Water pressure is allowed to the control valve and the plumbing system while not allowing water
to exit from the control valve to the plumbing system.
(valves shown with optional meters)