10
|
14
1.4)
Specification
Performance
Value
Performance
Value
Input voltage
100 ~ 240 V
Switch voltage
55
V
Input frequency
50 / 60 Hz
Switch frequency
50 / 60 Hz
Input current
max. 5
A
Switch current
0
.
6
A
PoE budget
360 W
Max. power consumption
380 W
Max. PoE per port
30 W (af + at)
PoE ports
24
x 100 Mb/s
(LAN: 1 ~
24
)
MAC address table
16
K
Uplink ports
2x 10
00 Mb/s
(LAN 25
~ 2
6)
Functions
Link & PoE 250 m (@ max. 10 Mb/s)
with VLAN
;
VLAN
;
disabling PoE ports
from the largest to the smallest (by numbering) after exceeding the PoE
budget
2)
The importance of individual elements
2.1)
LEDs and their meaning
Lanberg’s
rack
type
PoE
switch, has, on the front panel, multiple LEDs. Their number and meaning may
vary depending on your model. The below
-
displayed table contains an explanation of each LED regardless
of the rack switch model.
LED
Meaning
Solid LED
Blinking LED
LED is turned off
Power
Power
Device is turned
on
-
Device is turned
off
1 – 24
Port
(LAN / Ethernet
with PoE+)
Green color:
Device is
connected
Green color:
Data
transmission /
reception is in
progress
Green color:
Device is
not
connected
Orange color:
Device with PoE
mode is
connected
Orange color:
An error has
occurred with
PoE power
transmission or a
device without
PoE
has been
connected
25
– 26
Port
(LAN / Ethernet
/
SFP)
Device is
connected
Data
transmission /
reception is in
progress
Device is not
connected
The front of the switch housing lists separately the LEDs indicating Ethernet connection status
-
the section
in the box labeled with the signature
„
LINK / ACT
”
, and PoE status
–
the LEDs located under the ports. The