Eye protection filter faulty 

Arrange to have eye protection unit 
replaced by authorised customer 
service personnel 

 

IMAGE QUALITY 

Poor resolution 

Oculars dirty. 

Clean oculars. 

Marks or soiling in field of vision 

Oculars dirty. 

Clean oculars. 

 

 

Protective glass dirty 

Clean or exchange protective glass 

 

* Note: Marks in the field of vision can also be caused by soiling in the interior of the oculars. For this reason, it is 
recommended to have the lenses cleaned by an authorised customer service engineer 

 

PROBLEMS WITH MECHANICAL COMPONENTS 

Focus is not retained 

The sight slides down 

Readjust the tension of the focusing 
knob 

 
 
REPAIR 
If  the  stereo  microscope  requires  repair  or  adjustment  by 
qualified personnel, we recommend sending it back to the 
dealer  (authorized  customer  service)  in  its  original 

packaging.  Include  a  description  of  the  problem  or  the 
desired adjustment.  

 

WARNING: THE DEVICE MAY ONLY BE OPENED BY AUTHORIZED CUSTOMER SERIVICE PERSONNEL! 
 

 
 

11. SPARE PARTS LIST 

 

 

 

 

 

 

 

Hand piece 

(40) 

Nozzle (D 3mm) 

(41) 

Clamping nut 

(42) 

Chuck 

(43) 

Hand piece complete 

Electrodes: 

10 x electrodes D 0.5 mm (thorium oxide free), 
incl. diamond grinding disk  

10 x electrodes D 0.6 mm (thorium oxide free), 
incl. diamond grinding disk 

Grinding disk: 

diamond grinding wheel 

Gas hose: 

3m gas hose 6x4mm  

 

100 150K 

100 152 

100 151 

100 100 04 

 

100 400 

 

100 401 

 

100 701 

 

100 153

 

 

PLEASE NOTE! 

Nozzle

(40), clamping nut (41), electrodes and clamping tongs (42) are wearing parts and are not covered by the 

guarantee. 

 

 

Summary of Contents for PUK U4

Page 1: ...Operating Manual PUK U4...

Page 2: ...OPERATION THE GENERAL SAFETY REQUIREMENTS AND PERSONAL BODY PROTECTION CHAPTERS MUST BE READ BEFORE COMMISSIONING Please keep these operating instructions safe The equipment produced by Lampert Werkt...

Page 3: ...election of the TIG welding parameters Pg 11 6 2 Help function Pg 12 6 3 Programming Pg 12 6 4 Loading saved WIG welding programs Pg 13 6 5 Resistance welding mode Pg 13 7 WELDING INSTRUCTIONS 7 1 Int...

Page 4: ...the mains and welding currents can be a source of danger Always remove the mains plug when exchanging the LED unit Only use original replacement LED units from Lampert The device must be isolated from...

Page 5: ...in protection class 10 In addition to light and thermal radiation which can cause dazzling and burning the electric arc also emits UV radiation With insufficient protection this invisible ultraviolet...

Page 6: ...ET FOR LED MICROSCOPE ILLUMINATION 6 TYPE PLATE 7 SERIAL NUMBER 8 PROTECTIVE GAS CONNECTION ARGON GAS for 6 0 mm diameter pressure hose 9 APPROVED MAINS VOLTAGE FOR THIS DEVICE 10 USB SOCKET FOR SERVI...

Page 7: ...up hand tight do not use a tool to tighten The correct length for the electrode can easily be checked and corrected if necessary by means of the milled marks on the handpiece clamping arm Fig 4 Now re...

Page 8: ...interocular distance should be individually set for each user FOCUSING Mount a welding handpiece with clamped electrode into the supporting arm Rotate the focusing knob 22 to a medium focus range Adj...

Page 9: ...as resistance welding devices 29 CONNECTION SOCKET FOR HAND PIECE 30 SOCKET 6 mm socket for connecting the blue contact terminal for resistance welding as well as resistance welding devices TOUCHSCREE...

Page 10: ...d custom settings c Resistance welding mode d Settings In user level TIG welding it is possible to use the arrow keys to scroll back and forth between the various pages e g between the preconfigured p...

Page 11: ...GS The Settings user level can be used to modify basic settings and launch various test functions Gas Test Pressing the corresponding button causes the gas valve to be opened This function is importan...

Page 12: ...welding time Welding times of no more than 4ms are recommended here With many alloys and other highly conductive metals a longer welding time can be advantageous in order to avoid hot cracks starting...

Page 13: ...e Use identical alloy wire with a diameter of 0 3 to 0 4 mm Particularly low energy fusing of thin welding wires of a max 0 25 mm PUSHING TOUCHING THE RESPECTIVE BUTTON FOR AN EXTENDED PERIOD BRINGS U...

Page 14: ...FUNCTION OF THE EYE PROTECTION FILTER AS DESCRIBED IN CHAPTER 5 5 FILTER TEST IF THE EYE PROTECTION FILTER SHUTTER FAILS TO SWITCH OVER FROM LIGHT TO DARK THEN IT MUST BE IMMEDIATELY EXCHANGED BY AUT...

Page 15: ...e black When the two parts are touching the welding process can be triggered using the foot switch The hand piece is not used during this process The required welding power is determined by the streng...

Page 16: ...HAT ARE NOT DESCRIBED IN THESE OPERATING INSTRUCTIONS ARE NECESSARY THEN CONTACT YOUR DEALER WARNING IF FUSES REQUIRE EXCHANGING THEN THEY MUST BE REPLACED WITH FUSES OF THE SAME TYPES AND VALUES THE...

Page 17: ...ly in dry rooms Operating temperature Lamp LED unit Protection class Insulation class Protection type Weight 5 C to 40 C 2 5W 800mA III B IP 20 3 6 Kg 9 3 OPTICAL DATA MICROSCOPE Lens Ocular Working d...

Page 18: ...load Tungsten inert gas welding Earthing earth Nominal welding current Power consumption under max load Power consumption under nominal load Cyclic duration factor Single phase transformer Keep away f...

Page 19: ...firmly 7 Oxidation and rusting Excessive gas pressure Reduce flow rate approx 2 l min is recommended 8 Severe oxidation of the welding points Incorrect shielding gas Use inert shielding gas Argon 4 6...

Page 20: ...ocusing knob REPAIR If the stereo microscope requires repair or adjustment by qualified personnel we recommend sending it back to the dealer authorized customer service in its original packaging Inclu...

Page 21: ...e disposal of used electrical and electronic equipment discarded electrical devices must be separated and collected and sent for recovery in an environmentally friendly manner 13 EC DECLARATION OF CON...

Page 22: ...Born in Germany Lampert Werktechnik GmbH Ettlebener Stra e 27 D 97440 Werneck Tel 49 9722 9459 0 mail lampert info www lampert info Rev 4 0...

Reviews: