background image

 

¬

Only the Universal Disk Cover (Code 1719) can be used with the WaterLink Spin 

Touch.

 

¬

Empty syringe of old sample before filling with next sample.

 

¬

Remove filled disk from meter after testing. Do not travel with filled disks in meter. 

They may leak.

 

¬

Keep the chamber clean and dry. Gently swab LED and photodiode lenses located 

around the hub with a cotton swab dampened with streak-free window cleaner. 

Do not use alcohol. It will leave a thin film over the lenses when dry.

 

¬

Hold syringe vertically when filling disks.

 

¬

Store disks at 70°-80°F/21°-27°C.

MAINTENANCE 

CLEANING

  The optical system of the WaterLink Spin Touch must be kept clean and 

dry for optimal performance. Dry the disk with a lint-free wipe before placing it into 

the chamber to avoid introducing moisture. For best results, store the instrument 

in an area that is dry and free from aggressive chemical vapors. Clean the exterior 

housing with a damp, lint-free cloth. Do not allow water to enter the light chamber 

or any other parts of the meter. To clean the light chamber and optic lenses, point a 

can of compressed air into the light chamber and the lid and blow the pressurized air 

into the light chamber and lid. Focus the pressurized air around the LEDs which are 

the small round lenses positioned at 2:00, 4:00, 6:00, 8:00, 10:00 and 12:00 in the 

lid. The photodiodes are located on the bottom of the chamber around the hub. This 

area must be kept clean and dry. Use a cotton swab dampened with Windex

®

 window 

cleaner to gently swab the LED and photodiode lenses. Do not use alcohol; it will 

leave a thin residue over the optics when dry.
Remove smudges due to routine use from the touchscreen with the Cloth Wipe

 

(Code 3580-WIPE). Use a cloth dampened with alcohol for more thorough cleaning 

when necessary. Do not use Windex window cleaner, or similar cleaners, on the 

touchscreen.

RETURNS

  Should it be necessary to return the meter, pack the meter carefully in 

a suitable container with adequate packing material. A return authorization number 

must be obtained from LaMotte Pacific emailing 

[email protected]

Often a problem can be resolved over the phone or by email. If a return of the meter 

is necessary, attach a letter with the return authorization number, meter serial 

number, a brief description of problem and contact
information including phone and FAX numbers to the shipping carton.

METER DISPOSAL

  Waste Electrical and Electronic Equipment (WEEE). Natural 

resources were used in the production of this equipment. This equipment may 

contain materials that are hazardous to health and the environment. To avoid harm 

to the environment and natural resources, the use of appropriate take-back systems 

is recommended. The crossed out wheeled bin symbol on the meter encourages the 

use of these systems when disposing of this equipment. 

Take-back systems will allow the materials to be reused or recycled in a 

way that will not harm the environment. For more information on approved 

collection, reuse, and recycling systems contact local or regional waste 

administration or recycling services. Do not incinerate the equipment

DISK DISPOSAL

  The disks cannot be reused. Over time, the water in reacted disks 

will eva3porate. Disks can be recycled. Warning: Recyclers should check with the 

local authorities. Some states may require that no chemical residue remains on the 

plastic or may not be able to accept plastic waste with stainless steel mixing beads. 

Used disks may be returned, at the customer’s expense, to LaMotte for recycling. 

GENERAL INFORMATION

PACKAGING AND RETURNS

  Experienced packaging personnel at LaMotte 

Company assure adequate protection against normal hazards encountered 

in transportation of shipments. After the product leaves the manufacturer, all 

responsibility for its safe delivery is assured by the transportation company. Damage 

claims must be filed immediately with the transportation company to receive 

compensation for damaged goods. Should it be necessary to return the instrument, 

pack the instrument carefully in a suitable container with adequate packing material. 

A return authorization number must be obtained from LaMotte Company by calling 

1-800-344-3100 or 1-410-778-3100, ext. 3 or emailing 

softwaresupport@

lamotte.com

. Attach a letter with the authorization number to the shipping carton 

which describes the kind of trouble experienced.

GENERAL PRECAUTIONS

  Read the instruction manual before attempting to set 

up or use the instrument. Failure to do so could result in personal injury or damage 

to the meter. The WaterLink Spin Touch should not be stored or used in a damp 

or excessively corrosive environment. Care should be taken to prevent water or 

reagents from entering the photometer chamber. Wet disks should never be put into 

the photometer chamber.

SAFETY PRECAUTIONS

  Read the safety precautions on the labels of all reagent 

containers and packaging prior to use. Safety Data Sheets (SDS) can be found at 

www.lamotte.com

. Additional emergency information for all LaMotte reagents is 

available 24 hours a day from the National Poison Control Center at 1-800-222-

1222 or by contacting the 24 hour emergency line for ChemTel at 1-800-255-3924 

(USA, Canada, Puerto Rico). For locations outside of the North American continent 

call 813-248-0585 collect.

Ensure that the protection provided by this equipment is not impaired. Do not install 

or use this equipment in a manner that is not indicated in this manual.

LIMITS OF LIABILITY

  Under no circumstances shall LaMotte Company be liable for 

loss of life, property, profits, or other damages incurred through the use or misuse of 

its products.

CE MARK

 

 The WaterLink Spin Touch meter has been independently tested and has 

earned the European CE Mark of compliance for electromagnetic compatibility and 

safety. To view certificates, go to the LaMotte website at 

www.lamotte.com

.

This device complies with Part 15 of the FCC rules. Operation is subject to the 

following two conditions (1) This device may not cause harmful interference, and (2) 

this device must accept any interference received, including interference that may 

cause undesired operation.
Note: This equipment has been tested and found to comply with the limits for a Class 

B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to 

provide reasonable protection against harmful interference when the equipment 

is operated in a residential environment. This equipment generates, uses, and can 

radiate radio frequency energy and, if not installed and used in accordance with 

the instruction manual, may cause harmful interference to radio communications. 

However, there is no guarantee that interference will not occur in a particular 

installation. If this equipment does cause harmful interference to radio or television 

reception, which can be determined by turning the equipment off and on, the user 

is encouraged to try to correct the interference by one or more of the following 

measures:

 

¬

Reorient or relocate the receiving antenna.

 

¬

Increase the separation between the equipment and receiver.

 

¬

Connect the equipment into an outlet on a circuit different from that to which the 

receiver is connected.

 

¬

Consult the dealer or an experienced radio/TV technician for help.

NSF CERTIFICATION

  

The NSF/ANSI/CAN 50 certification mark on a water quality 

testing device (WQTD) used in recreational waters, such as pools and spas, 

means that the product was reviewed and certified by NSF International 

to meet applicable American National Standards for product design 

and performance. NSF tests and re-tests products to confirm that they 

comply with all requirements of certification for performance, accuracy 

and operating range. Certification levels of L1, L2, and L3 are possible with L1 being 

the highest rating. Go to 

www.nsf.org

 for more information.

For the most recent WaterLink Connect 2 update and the most recent Spin Touch 

firmware update, customers who intend to use a WaterLink Spin Touch Meter for 

NSF certification compliance purposes should:
1.  Visit 

softwarecenter.lamotte.com

 and download the WaterLink Connect 2 

application for Windows.

2.  Plug the Spin Touch into the computer using the included USB cable.
3.  Open the WaterLink Connect 2 desktop application and wait for the update to 

complete.

NSF Level

Test Factor

Application

NSF Certified Range Accuracy/Overall

pH

Pool

6.4–8.6

L1

Spa/Hot Tub

6.4–8.6

L1

Free Chlorine

Pool

0–15 ppm

L1

Spa/Hot Tub

0–7 ppm

L1

Chlorine, Combined Pool

0-1 ppm

L2

Spa/Hot Tub

0-1 ppm

L2

Cyanuric Acid

Pool

5–50 ppm

L1

Effective April 2022. Based on a 12 month shelf life. Other test factors not evaluated 

by NSF.
Go to 

www.NSF.org

 to review the latest levels, ranges, shelf life, firmware versions 

supported, and a current listing of LaMotte NSF 50 certified products.

WARRANTY

  LaMotte Company warrants this instrument to be free of defects 

in parts and workmanship for 2 years from the date of shipment. Keep the proof 

of purchase for warranty verification. If it should become necessary to return 

the instrument during or the warranty period, contact LaMotte Pacific emailing 

[email protected]

. for a return authorization number or visit 

www.lamotte.com

 for troubleshooting help. The sender is responsible for shipping 

charges, freight, insurance, and proper packaging to prevent damage in transit. This
warranty does not apply to defects resulting from action of the user such as misuse, 

improper wiring, operation outside of specification, improper maintenance or repair, 

or unauthorized modification. LaMotte Company specifically disclaims any implied 

warranties or merchantability or fitness for a specific purpose and will not be liable 

for any direct, indirect, incidental, or consequential damages. LaMotte Company’s 

total liability is limited to repair or replacement of the product with a new or 

refurbished meter as determined by LaMotte Company. The warranty set forth above 

is inclusive and no other warranty, whether written or oral, is expressed or implied.

Certified to

NSF/ANSI/CAN 5

0

3580-QG-AU-A4  |  EN  |  

05.09.2023

Water Testing Leader Since 1919

Disk US Patent No. 8.734.734    

FCl US Patent No. 8.987.000  

FCl EU Patent No. EP2784503 A1 

TCl US Patent No. 8.993.337

Australia and New Zealand Support

1300-723-488 • support@lamottepacific.com.au

LaMotte Pacific 

2/6 Bonz Place, Seven Hills, NSW 2147 

PO Box 345, Seven Hills, NSW 1730

LaMotte, WaterLink, Spin Touch are ® registered 

trademarks of LaMotte Company

 

© 2023 LaMotte 

Company, All Rights Reserved

Summary of Contents for WaterLink SpinTouch 3580-AU

Page 1: ...SF ANSI CAN 50 2023 LaMotte Company All Rights Reserved For Code 3580 AU 3581 AU 05 09 2023 Scantoaccess download andprint theSpinTouchQuickStartGuide WARNING only use the USB cable and wall adapter t...

Page 2: ...a mobile device requires that a mobile app is installed on the device and an active account for the associated software program For example with an active WaterLink Solutions account and the WaterLink...

Page 3: ...at a time Auto Save Tests must be disabled If Auto Save Tests is disabled will be highlighted on the Test Results screen After the test has been run tap to save the results for that water sample to th...

Page 4: ...d at low battery power without connecting it an AC power source the meter will go into an auto shutdown mode In this mode the meter will be locked until meter is connected to an AC source and the batt...

Page 5: ...k Free Chlorine Bromine Free Chlorine Bromine Total Chlorine Total Chlorine Chlorine Bromine pH Alkalinity Code4335 Series601 pH Free Chlorine Bromine Alkalinity pH Free Chlorine Bromine Alkalinity Bl...

Page 6: ...IMPORTANT DonotattempttoseparatethecomponentsoftheMeterCheckDisk Code1705 1705 EU TheMeterCheckDiskconsistsofadiskwithapermanently attachedcover DonotfilltheMeterCheckDiskwithwater Waterisnotusedinth...

Page 7: ...emergency line for ChemTel at 1 800 255 3924 USA Canada Puerto Rico For locations outside of the North American continent call 813 248 0585 collect Ensure that the protection provided by this equipmen...