background image

11

EXPAND YOUR TRACER

LaMotte Company warrants this instrument to be free of defects in parts and 

workmanship for 1 year from the date of shipment and this probe be free of 

defects in parts and workmanship for 6 months from the date of shipment. The 

sender is responsible for shipping charges, freight, insurance and proper 

packaging to prevent damage in transit This warranty does not apply to defects 

resulting from action of the user such as misuse, improper wiring, operation 

outside of specif  cation, improper maintenance or repair, or unauthorized 

modif  cation. LaMotte Company specif  cally disclaims any implied warranties 

or merchantability or f  tness for a speci f  c purpose and will not be 

liable for 

any direct, indirect, incidental or consequential damages. LaMotte 

Company’s total liability is limited to repair or replacement of the product. The 

warranty set forth above is inclusive and no other warranty, whether written 

or oral, is expressed or implied.

Test Equipment Depot - 800.517.8431 - 99 Washington Street Melrose, MA 02176

 TestEquipmentDepot.com 

Summary of Contents for ORP PockeTester Tracer

Page 1: ...Water Testing Leader Since 1919 Tracer ORP PockeTesterTM Code 1742 99 Washington Street Melrose MA 02176 Phone 781 665 1400 Toll Free 1 800 517 8431 Visit us at www TestEquipmentDepot com...

Page 2: ...Display 5 Basic Operation Powering the TRACER 6 Electrode Recognition 6 Automatic Calibration 6 Data Hold 6 ORP Testing Overview 6 ORP Display 6 Getting Started 6 ORP Measurement 6 Storing Readings 7...

Page 3: ...unction display with bar graph Operating conditions 32 to 122 F 0 to 50 C and 80 RH ORP Range Accuracy 999mV 4mV Measurement storage 15 readings numbered readings Low battery indicator BAT appears on...

Page 4: ...ver 2 LCD Display 3 MODE HOLD button 4 CAL RECALL button 5 ON OFF button 6 Electrode Collar 7 Electrode Sensor Note The Electrode storage cap is not shown LCD Display 1 Reading 2 Units 3 Bargraph 4 Da...

Page 5: ...Hold Press the MODE HOLD button to freeze the current reading The HOLD display icon will appear along with the held reading The held reading will be stored in the next 15 reading storage location Pre...

Page 6: ...1 to store the next reading 7 If an attempt is made to store more than 15 readings the stored readings starting with the f rst reading will be overwritten Recalling Stored Readings NOTE First ensure t...

Page 7: ...Store vertically Battery Replacement 1 Twist off the battery compartment cap 2 Hold the battery housing in place with one f nger Remove the battery carrier by pulling on the small tabs 3 Replace the...

Page 8: ...ars Display frozen HOLD function Press MODE or turn meter off Button response Remove batteries stored data will be lost Steady 1 display Wait Reading not stable yet REPLACING THE ELECTRODE The TRACER...

Page 9: ...des Total Chlorine TRACER Electrode 0 00 10 00 ppm The Total Chlorine TRACER Electrode Code 1732 requires the use of TRACER TCL Tablets Order Code 7044A J 100 pack Code 1732 pH TRACER Electrode 0 00 1...

Page 10: ...of the user such as misuse improper wiring operation outside of specif cation improper maintenance or repair or unauthorized modif cation LaMotte Company specif cally disclaims any implied warranties...