Using the product

 

 

To dispense hot water:  

 

Fully depress the left hand lever (fig 1.) 
and then simultaneously turn the handle 
forwards (fig 2.), the further forwards the 
lever is turned the greater the flow. 
 
At around 45° rotation is reached (fig 2.) 
the maximum flow is achieved. 
 
It is normal for the hot water to take a 
moment to dispense as the water empties 
from the product after each use, once the 
handle is closed water will continue to run 
until the spout has emptied. 
 
 

 

 

Fig 1.               

Fig 2.  

 

⚠ 

Should you see that hot water persistently drips from the centre channel of the tap spout (when the tap is not in use 

and the boilers indicator red light is switched on) then you should reduce the temperature adjustment dial on the top of 
the boiler, see the boiler user manual for further detail.

 

 

Each time the product is used you should flush a small amount of boiled water through before use, typically this can be 
used to preheat your cup, if unused for extended periods then flush the product a longer time. 

 

 

WARNING: THIS APPLIANCE CAN BE USED BY CHILDREN AGED FROM 8 YEARS AND ABOVE 

AND PERSONS WITH REDUCED PHYSICAL, SENSORY OR MENTAL CAPABILITIES OR LACK OF 
EXPERIENCE AND KNOWLEDGE ONLY IF THEY HAVE BEEN GIVEN SUPERVISION OR INSTRUCTION 
CONCERNING USE OF THE APPLIANCE IN A SAFE WAY AND HAVE UNDERSTAND THE HAZARDS 
INVOLVED. CHILDREN SHALL NOT PLAY WITH THE APPLIANCE. CLEANING AND USER 
MAINTENANCE SHALL NOT BE MADE BY CHILDREN. ALL WIRING AND INSTALLATION MUST BE 
SUPERVISED BY A SUITABLY QUALIFIED PERSON.

 

 

Do not add to, exchange or modify any component of the boiler or mixer tap, only genuine parts must be 

used. The spout exit or any part of the system must not include any additional third party adaptors, 
components or connections that will add resistance or modify the system. 

 

The installation should be periodically checked for damage, if the property is left unattended for a 

prolonged period we recommend isolating water supplies and switching off the boiler at the mains socket, on 
reconnection flush thoroughly. 

 

 
 
 
 
                                                                                                                                                                                                 
 
 
 
 
 
 
 
 

 
 
 
 

Please leave these instructions for your customer. 

                                                                                                                                                                                                 ref/tap6000v1 

Summary of Contents for TAP6000

Page 1: ...nce Important Technical Data Minimum operating pressure hot 0 75 bar Minimum operating pressure cold 2 5 bar with filter 1 0 bar without filter Maximum operating pressure 5 5 bar Maximum domestic hot water temperature 70 C Flow characteristics Domestic Hot Cold share outer single flow spout Boiled water Through centre spout channel Recommended domestic hot water temperature 46 C If these temperatu...

Page 2: ...enance Ensure you have suitable domestic hot and cold water pressure before installing this product see technical data for more information All parts should be removed from their packaging and inspected for any transport damage and that all parts are present prior to installation Shut off your water heating system and ensure that your mains stopcock is closed Open the lowest hot and cold taps in t...

Page 3: ...r boiler flexible hose including seal 1 C2 3 8 M x F adaptor 1 C3 NPT M x pushfit 1 C4 outside diameter plastic pipe 1 C5 Filter bracket screw 1 C6 Filter bracket 1 C7 Filter cartridge 1 D1 110 rated hot water hose from boiler output 1 D2 3 8 fibre seal 1 E1 Boiler 1 E2 Flexible boiled water output pipe 1 E3 Connecting tundish assembly 1 E4 Flexible drain pipe 1 Part supplied with boiler pack For ...

Page 4: ...t the filter cartridge C7 under the sink it must be mounted vertically as shown easily accessible to be changed periodically away from any heat source and close enough not to exceed the available length of the plastic pipe C4 supplied 2 Using the self tapping screw C5 securely fix the filter bracket C6 to the cabinet wall 3 Write the installation date onto the filter label in permanent pen then cl...

Page 5: ...xtended periods then flush the product a longer time WARNING THIS APPLIANCE CAN BE USED BY CHILDREN AGED FROM 8 YEARS AND ABOVE AND PERSONS WITH REDUCED PHYSICAL SENSORY OR MENTAL CAPABILITIES OR LACK OF EXPERIENCE AND KNOWLEDGE ONLY IF THEY HAVE BEEN GIVEN SUPERVISION OR INSTRUCTION CONCERNING USE OF THE APPLIANCE IN A SAFE WAY AND HAVE UNDERSTAND THE HAZARDS INVOLVED CHILDREN SHALL NOT PLAY WITH...

Reviews: