background image

Tap & Filter installation 

 

This diagram shows the view of the base of the tap (A1) with the 
boiling water handle to the left of the body. 

 

 

 

Install the Tap: 

 

 

 

This diagram 
shows the 
markings on 
boiler (E1) to 
indicate the inlet 
and outlet, see 
the boiler 
instructions for 
further detail. 

 

  

boiler hot water outlet 

 

boiler cold water inlet 

1.  Screw the fixing stud (A8) into the base of tap (A1) as shown on the diagram. 

 

2.  Place the base plinth (A2) and base plinth seal (A3) onto the base of the tap (A1). 

 

3.  Hand tighten the domestic hot flexi hose (B6) into the base of tap (A1) as shown in the diagram above. 

 

4.  Hand tighten the domestic cold flexi hose (B1) into the base of tap (A1) as shown in the diagram above. 

 

5.  Hand tighten the cold out flexi hose (C1) into the base of tap (A1) as shown in the diagram above. 

 

6.  Hand tighten the 110° rated hot flexi hose (D1) into the centre inlet as shown on the diagram and marked on the tap body. 

 

7.  Place the tap (A1-A3) centrally and straight to the tap hole, passing the fixing stud (A8), flexi hoses (B1, B6, C1, D1) through the 

tap hole. 

 

8.  Pass the lower gasket (A6) then the metal horseshoe (A7) over the fixing stud (A8).  Note: only if the tap is to be fitted to a 

stainless steel sink then the white triangular plate (A5) can be fitted where shown to improve the stability of the tap. 

 

9.  Using an 13mm box spanner or small adjustable spanner tighten fixing nut (A9) onto the fixing stud (A8). 

 

10. 

Screw pushfit (C3) into adaptor (C2), 

we recommend using PTFE tape (do not use sealing compound) on the thread of 

pushfit (C3) to make a good seal without applying excessive force (which may damage the plastic pushfit if 
overtightened). 

 

11.  Screw pushfit (C3) and adaptor (C2) into the cold out flexi hose (C1).  

 

12.  Connect the cold water flexi hose (B1) to the cold water isolation valve (B5) using a section of 15mm pipe (B4) and compression 

nuts (B3) and olives (B2). Repeat the process to connect the domestic hot flexi hose (B6) to the domestic hot water supply.  

 

Install the Filter: 

 

1.  Find a suitable place to mount the filter cartridge (C7) under the sink, it must be mounted vertically as shown, easily accessible 

(to be changed periodically), away from any heat source and close enough not to exceed the available length of the ¼” plastic 
pipe (C4) supplied. 

 

2.  Using the self-tapping screw (C5) securely fix the filter bracket (C6) to the cabinet wall.  

 

3.  Write the installation date onto the filter label in permanent pen then clip the filter cartridge (C7) into the bracket (C6) as shown. 

You must respect the direction of flow as indicated. 

 

4.  Measure and then cut required length of ¼” pipe (C4) to connect pushfit (C3) to the filter cartridge (C7) inlet, then from the filter 

cartridge (C7) outlet to the boiler inlet (E1) leave a little additional length on both pipes to allow the filter cartridge (C7) to be 
unclipped and replaced more easily by the customer. The ¼” pipe (C4) must be cut cleanly and squarely with a sharp tube snip. 

 

5.  Firmly push connect the ¼” pipe (C4) between pushfit (C3) and filter cartridge inlet (C7), repeat this from the filter cartridge (C7) 

outlet to the boiler inlet (E1). 

 

After installation of the tap and filter is complete 

 

1.  Please refer to ‘boiler installation and user guide’ for the next steps and complete the installation. 

Do not plug in the boiler until 

advised.

 

 

2.  Reconnect the domestic hot and cold water supplies then open isolation valves (B5). As the system starts to refill, check carefully 

all new water connections for leaks. After the product installation is complete we recommend you recheck for any slower leaks. 

 

3.  Turn on the hot water handle fully, keep the lever open until all air is expelled and cold (unboiled) water exits the centre channel 

of the tap spout, flush a further 10 litres of cold (unboiled) water through the filter, boiler and tap. You may notice a discolouration 
to the water at first, this is loose carbon fines from the optional filter it is normal, harmless and will pass with flushing. Once 
complete turn off the left hand hot water handle. 

 

4.  Plug in and switch on the boiler, wait until the water has finished heating fully. 

 

5.  Clean the tap with a damp soft cloth and a mild dish soap to remove any grease marks created during installation as per the care 

instructions.  

Summary of Contents for TAP6000

Page 1: ...nce Important Technical Data Minimum operating pressure hot 0 75 bar Minimum operating pressure cold 2 5 bar with filter 1 0 bar without filter Maximum operating pressure 5 5 bar Maximum domestic hot water temperature 70 C Flow characteristics Domestic Hot Cold share outer single flow spout Boiled water Through centre spout channel Recommended domestic hot water temperature 46 C If these temperatu...

Page 2: ...enance Ensure you have suitable domestic hot and cold water pressure before installing this product see technical data for more information All parts should be removed from their packaging and inspected for any transport damage and that all parts are present prior to installation Shut off your water heating system and ensure that your mains stopcock is closed Open the lowest hot and cold taps in t...

Page 3: ...r boiler flexible hose including seal 1 C2 3 8 M x F adaptor 1 C3 NPT M x pushfit 1 C4 outside diameter plastic pipe 1 C5 Filter bracket screw 1 C6 Filter bracket 1 C7 Filter cartridge 1 D1 110 rated hot water hose from boiler output 1 D2 3 8 fibre seal 1 E1 Boiler 1 E2 Flexible boiled water output pipe 1 E3 Connecting tundish assembly 1 E4 Flexible drain pipe 1 Part supplied with boiler pack For ...

Page 4: ...t the filter cartridge C7 under the sink it must be mounted vertically as shown easily accessible to be changed periodically away from any heat source and close enough not to exceed the available length of the plastic pipe C4 supplied 2 Using the self tapping screw C5 securely fix the filter bracket C6 to the cabinet wall 3 Write the installation date onto the filter label in permanent pen then cl...

Page 5: ...xtended periods then flush the product a longer time WARNING THIS APPLIANCE CAN BE USED BY CHILDREN AGED FROM 8 YEARS AND ABOVE AND PERSONS WITH REDUCED PHYSICAL SENSORY OR MENTAL CAPABILITIES OR LACK OF EXPERIENCE AND KNOWLEDGE ONLY IF THEY HAVE BEEN GIVEN SUPERVISION OR INSTRUCTION CONCERNING USE OF THE APPLIANCE IN A SAFE WAY AND HAVE UNDERSTAND THE HAZARDS INVOLVED CHILDREN SHALL NOT PLAY WITH...

Reviews: