No shelf or overhang of combustible material should be closer than 650mm directly above the hob.
There must be a minimum clearance of 50mm between the rear edge of the hob and the rear wall. This
clearance must be maintained up to 650mm above the worktop (unless otherwise stated in your extractor
manual).
Apply the self adhesive seal around the perimeter of the worktop cut-out. For best results, the seal should
be adhered along each side in turn, as close to the edge as possible, and trimmed at each corner, taking
care to ensure a neat join.
14
Clearances and dimension requirements
LAMONA
Appliances
Installation
560mm +2
50mm Min
55mm min
400mm min
490mm +2
Minimum distance
between cabinets
must be equal to
the width of the hob
*
Minimum height to extractor
as recommend in extractor
instruction manual
*
50mm min between hob and rear wall
(>60mm to cut out aperture)