21
Instructions and Installation
NOTICE:
If the gas type of
the unit is changed, then the
rating plate that shows the
gas type of the unit must also
be changed.
Regulating the
minimum flame
After lighting the burners, turn
the control knob to the minimum
setting then remove the knob
(this can easily be removed by
applying gentle pressure).
Using a small
«
terminal
»
type
screwdriver the regulating
screw can be adjusted as in
image shown. Turning the screw
clockwise reduces the gas flow,
whilst turning it anticlockwise
increases the flow - use this
adjustment to obtain a flame of
approximately 3 to 4mm in length
finally, replace the control knob.
When the gas supply
available is LPG.
The screw to set the idle flame
must be turned clockwise to the
end stop.
When you have carried out the
new gas regulation, replace
the old gas rating plate on your
appliance with one (supplied with
hob) suitable for the type of gas
for which it has been regulated.