Install the tap:
This diagram shows the view of the
base of the tap (A1) with the 98°C
water handle to the left of the body.
⚠
YOU MUST
CAREFULLY
RESPECT THE
INLETS AND
OUTLETS AS SHOWN
Install the tap:
1. Screw the fixing stud (A8) into base of tap (A1) as shown on the diagram.
2. Place the base plinth (A2) and base plinth seal (A3) onto the base of the tap (A1).
3. Hand tighten the domestic hot in flexible hose (B1) as shown in the diagram.
4. Hand tighten the domestic cold in flexible hose (B6) as shown in the diagram.
5. Hand tighten the cold out flexible hose (C1) as shown in the diagram.
6. Hand tighten the 110° rated steaming hot flexible hose (D1) into the centre inlet as shown on the diagram.
7. Place the tap (A1-A3) centrally and straight to the tap hole, passing the fixing stud (A8), flexi hoses (B1, B6, C1, & D1) through
the tap hole.
8. Pass the lower gasket (A6) then the metal horseshoe (A7) over the fixing stud (A8). Note: only if the tap is to be fitted to a
stainless steel sink then the white triangular plate (A5) can be fitted where shown to improve the stability of the tap.
9. Using a 13mm box spanner or small adjustable spanner tighten fixing nut (A9) onto the fixing stud (A8).
10. Screw pushfit (C3) into brass adaptor (C2).
⚠
We recommend using PTFE tape (do not use sealing compound) on the thread of the pushfit fittings to make a good
seal without applying excessive force (which may damage the plastic pushfit if overtightened).
11. Screw pushfit (C3) and adaptor (C2) into the cold out flexible hose (B1).
12. Connect the domestic hot water flexible hose (B1) to the hot water isolation valve (B5) using a section of 15mm pipe (B4) and
compression nut (B3) and olive (B2).
13. Connect the domestic cold water flexible hose (B6) to the cold water isolation valve (B5) using a section of 15mm pipe (B4)
and compression nut (B3) and olive (B2).
⚠
If your customer has a water softener installed you must attach cold water flexible hose (B6) to an unsoftened cold
water source.