background image

 

 

SPECIFICATIONS 

 

The gas fire pit, with gas type I

3B/P(30), 

is designed to operate on Butane or Propane or their mixtures at 30mbar. 

Gas consumption, prefssures and injectors orifice sizes are listed in the below table. 

 

Appliance category 

Injector Orifice 

Nominal Heat Input (Hs) 

Gas Consumption (G30) 

I

3B/P(30)

 

2.09 mm 

16.5 kW 

1201 g/h 

 

DO  NOT

  use  this  appliance  with  an  adjustable  regulator.  We  suggest  you  use  this  appliance  with  a  4.5  kgs 

Butane gas cylinder. 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for FR01

Page 1: ...Gas consumption G30 1201 g h BE BG CY CZ DK EE FI FR GB GR HR HU IT LT LU LV MT NL NO RO SE SI SK TR Cat I3B P 30 Butane Propane and their mixtures at 30mbar Injector 2 09mm Only nationally approved h...

Page 2: ...lity 7 Please check the gas leakage with soap water do not use a fire 8 The appliance area must be kept clear and free from combustible materials gasoline and other flammable vapors and liquids 9 Do n...

Page 3: ...ip over it or in areas where the hose may be subject to accidental damage 23 Keep the fuel supply hose away from any heated surface 24 Never use this appliance closer than 3 meters from anything flamm...

Page 4: ...bar Gas consumption prefssures and injectors orifice sizes are listed in the below table Appliance category Injector Orifice Nominal Heat Input Hs Gas Consumption G30 I3B P 30 2 09 mm 16 5 kW 1201 g h...

Page 5: ...all parts from the box compare parts with package content listed above make sure all parts are present before beginning assembly of product If any part is missing or damaged do not attempt to assembl...

Page 6: ...ing clockwise to loosen or remove see Figure 2 Figure 2 4 Please use a flexible hose with a length less than 150cm 5 Please use a regulator complied with standard EN12864 6 Secure the cylinder by tigh...

Page 7: ...he push button cap on the igniter module located on the control panel to access the battery compartment The igniter module requires one AAA size battery WARNING 1 Please observe proper polarity and us...

Page 8: ...is defective and should replace the part LIGHTING INSTRUCTIONS 1 Push in gas control knob slightly and turn to OFF 2 Turn gas control knob the ON MIN 3 Push in gas control knob all the way and hold Co...

Page 9: ...t and render it unsafe for use Clean burner holes by using a heavy duty pipe clearer Compressed air may help clear away small particles 4 Carbon deposits may create a fire hazard Clean burner with war...

Page 10: ...onable or abusive use Fire pits that were clearance items display models or items purchased in an as is condition freight damage fire pit damaged by acts of nature vandalism fire abuse lack of proper...