Subject to change without notice.

Trigger threshold: 

0.1 m/s

Trigger threshold: 

0.1 m/s 

Interface: RS 

485

Protocols: Modbus 

RTU

Measuring rate: 

0.1...10 Hz

Supply voltage: 

6...60 VDC

 heating 

: 24 VAC/DC ± 20 %

Current Consumption:  Sensor: typ. 50 mA at 24 VDC
 

with heating: max. 10 A at 24 VAC/DC

Heating data: 

factory con

fi

 gurable: 60 W / 120 W / 

 

200 W (standard)

Dimensions: 

H 284 mm 

 Ø 199 mm 

 mast  adapter 

Ø 50 mm for mounting on standard pipe

Housing: seawater 

resistent 

aluminium

 

IP 66, IP 67

Weight: 

approx. 3.4 kg

Standards

• Modbus RTU
•  Standard of construction: VDE 0100
•  Low voltage guide line: 72/23 EWG
•  EMC/ EMI: DIN EN 60945 and DIN EN 61000-4-2, 3, 4, 6, 11
•  Salt fog: EN 60945
•  Protection class: DIN EN 60529

Accessories:

(please order separately)

32.14567.060010

Sensor cable, 15 m, 

 

4 pole M12 plug

Options:

(please order separately)

36.09340.000000

Visualization and evaluation software

MeteoWare-CS3

(except for global radiation)

00.95800.010000

 

Data logger met[LOG]

00.14742.401002

 

Display unit METEO-LCD/IND

(except for global radiation)

1

 Temperature in

fl

 uence of the shelter: ac1.5 °C at v < 2 m/s 

and intensive solar radiation

2

 Temperature in

fl

 uence of the shelter: 

± < 0.1 % r.h. at +10…+40 °C

3

 Shelter inaccuracy: < 4 % r.h. dependant on v > 2 m/s and solar 

radiation 

7 Technical 

data

(16480) Weather Sensor 

u[sonic]WS7 Modbus

Id-No. 00.16480.001130

Range of application: -40...+70 °C (heated: -50...+70 °C) • 

0...100 % r. h.

Parameters:

Wind direction

 Meas. 

principle:  ultrasonic

 Measuring 

range: 0...359.9°

  Accuracy: 

< 2° (>1 m/s) RMSE

 Resolution: 

0.1°

Wind speed

Meas. principle: 

ultrasonic

  Measuring range:  0...65 m/s
  Accuracy: 

± 0.2 m/s RMSE (v < 10 m/s) •

   

± 2 % RMSE (10 m/s < v < 65 m/s)

 Resolution: 

0.1 

m/s

Temperature 

  Meas. principle: 

digital temperature sensor

  Measuring range:  -40...+70 °C
  Accuracy: 

± 0.1 K (0...60 °C) 

1) 

• 

   

± 0.2 K (-40...0 °C) 

1)

 Resolution: 

0.1 

°C

Relative humidity

  Meas. principle: 

capacitive, digital

  Measuring range:  0...100 % r. h.
 Accuracy: 

± 

1.5 % (0...80 %) r. h. 

2)3)

   

± 2 % (>80 %) r. h.

  Resolution: 

0.1 % r. h.

Barometric pressure

 Meas. 

principle:  piezoresistive

  Measuring range:  300...1100 mbar
 Accuracy: 

± 

0.5 mbar

 Resolution: 

0.1 

mbar

Global radiation

 Meas. 

principle:  thermoelectric

  Measuring range:  0...2000 W/m² • Global radiation in the 

range of 285...3000 nm

 Accuracy: 

Second class

 Resolution: 

0.2 

W/m²

Dew point temperature

 Meas. 

principle:  passive • calculated from air temperature 

and humidity

  Measuring range:  -40...+70 °C
 Resolution: 

0.1 

°C

8

16480_WS7_b-de.indd     16.20

LAMBRECHT meteo GmbH 

 Tel 

+49-(0)551-4958-0

Friedländer Weg 65-67 

 Fax 

+49-(0)551-4958-312

37085 Göttingen 

  

E-Mail 

[email protected]

Germany 

  

Internet 

www.lambrecht.net

Summary of Contents for WS7

Page 1: ...y of measured values by using the evaluation software MeteoWare CS3 Simple space saving assembly on 50 mm standard pipe The perfect weather sensor For industrial use as well as under extreme environme...

Page 2: ...ing elements This heating is particularly e ective against ice and snow in all climatic zones The measuring principle allows very low starting valuesand high repeat accuracy The sensor rapidly can be...

Page 3: ...lly the earth screw has to be connected to the ship s ground Acid free contact grease is recommended to protect contact surfaces against corrosion Note Follow all safety instructions while setting up...

Page 4: ...safety regulations for such works During the electrical installation and termination works the external circuit breaker must be switched o It is not permitted to open those housings by unauthorized pe...

Page 5: ...sor u sonic WS7 Modbus 16480 001 u sonic WS7 Modbus Manual 5 Dimensional drawings and electrical connections u sonic WS7 Sensor side plug male M12 4 pin or 5 pin shielded Cable side socket female M12...

Page 6: ...gnificant byte is sent first For values that go beyond one register e g 32 bit this is not clearly specified for the Modbus In these cases 32 bit or 64 bit the LAMBRECHT Modbus sensors follow the big...

Page 7: ...or supports the corresponding values e g a pure wind sensor does not provide any air humidity The LAMBRECHT sensors give 0xD8F1 0xFF676981 as error code or invalid value 6 7 Holding register Register...

Page 8: ...rature influence of the shelter 0 1 r h at 10 40 C 3 Shelter inaccuracy 4 r h dependant on v 2 m s and solar radiation 7 Technical data 16480 Weather Sensor u sonic WS7 Modbus Id No 00 16480 001130 Ra...