Weather Sensor u[sonic]WS7 Modbus

(16480.001) u[sonic]WS7 Modbus    

 

      Manual

6.6 

Measured value and parameter register LAMBRECHT sensors

The register ranges 30001 to 35000 are intended for measured values.
The following measured values are provided by LAMBRECHT meteo sensors.

Register address Parameter name

Unit

Factor

Description

30001

Wind speed instantaneous value

m/s

10

1 decimal place

INT

30201

Wind direction instantaneous value

°

10

1 decimal place

INT

30401

Air temperature instantaneous value

°C

10

1 decimal place

INT

30601

Humidity instantaneous value

%r.h.

10

1 decimal place

INT

30701

Dew point instantaneous value

°C

10

1 decimal place

INT

30801

Air pressure instantaneous value

hPa

10

1 decimal place

INT

31401

Global radiation instantaneous value

W/m²

10

1 decimal place

INT

31501

Global radiation instantaneous values 
(High-WORD) (temperature compensated)

W/m²

100

2  decimal places
Registers 31591 + 
31592 can only be 
read out together. 
(function code 0x04

LONG

31502

Global radiation instantaneous values 
(Low-WORD) (temperature compensated)

31591

Global radiation instantaneous values 
(High-WORD) (uncompensated)

31592

Global radiation instantaneous values 
(High-WORD) (uncompensated)

The register addresses 30001 to 35000 apply to all LAMBRECHT meteo Modbus sensors, but are only available or valid if the 
respective sensor supports the corresponding values. (e.g. a pure wind sensor does not provide any air humidity).
The LAMBRECHT sensors give 0xD8F1 (0xFF676981) as error code or invalid value.

6.7 Holding 

register

Register address 40001 to 49000
Register address 40001 to 46000 contains the con

fi

 guration parameters of the sensor.

Registers Address 46001-49000 contain for each sensor the available registers with measured values and sensor data from 
the range 30001-35000.

6.8 

Sensor parameters / con

fi

 guration-parameters

Register address Parameter name

Unit

Factor

Description

40001

Modbus device address

1

The addresses 1...247 are allowed.

40200

Baud rate

0,01

96=9600
192=19200
384=38400

46000

Number of mapping-registers

1

Contains the number of occupied map-
ping registers for the autocon

fi

 guration

INT

6.9 

Mapping-Register for autocon

fi

 guration

Registers Address 46001-49000 containing for each sensor the available registers with measured values and sensor data 
from the range 30001-35000.
The registers can only be read out as a block! The length of the block or the number of available mapping registers is in hold-
ing register 46000
For example, in the Modbus Pro WG, registers 46001 to 46004 contain valid addresses. The holding register 46000 contains 
the number of registers 4, all 4 registers must be read out in the block with the instruction 0x04. Too many registers or too few 
lead to an error message.

6.10 Autocon

fi

 guration

Note: Detailed description of the autocon

fi

 guration, see “General Manual for LAMBRECHT meteo Modbus Sensors”.

7

Summary of Contents for WS7

Page 1: ...y of measured values by using the evaluation software MeteoWare CS3 Simple space saving assembly on 50 mm standard pipe The perfect weather sensor For industrial use as well as under extreme environme...

Page 2: ...ing elements This heating is particularly e ective against ice and snow in all climatic zones The measuring principle allows very low starting valuesand high repeat accuracy The sensor rapidly can be...

Page 3: ...lly the earth screw has to be connected to the ship s ground Acid free contact grease is recommended to protect contact surfaces against corrosion Note Follow all safety instructions while setting up...

Page 4: ...safety regulations for such works During the electrical installation and termination works the external circuit breaker must be switched o It is not permitted to open those housings by unauthorized pe...

Page 5: ...sor u sonic WS7 Modbus 16480 001 u sonic WS7 Modbus Manual 5 Dimensional drawings and electrical connections u sonic WS7 Sensor side plug male M12 4 pin or 5 pin shielded Cable side socket female M12...

Page 6: ...gnificant byte is sent first For values that go beyond one register e g 32 bit this is not clearly specified for the Modbus In these cases 32 bit or 64 bit the LAMBRECHT Modbus sensors follow the big...

Page 7: ...or supports the corresponding values e g a pure wind sensor does not provide any air humidity The LAMBRECHT sensors give 0xD8F1 0xFF676981 as error code or invalid value 6 7 Holding register Register...

Page 8: ...rature influence of the shelter 0 1 r h at 10 40 C 3 Shelter inaccuracy 4 r h dependant on v 2 m s and solar radiation 7 Technical data 16480 Weather Sensor u sonic WS7 Modbus Id No 00 16480 001130 Ra...

Reviews: