Technical Data 

 

 

(14966) power[cube]   

Ident-Nr. 00.14966.715 000

  

Output power-supply:   

  24 VDC 

Output voltage range:   

  24...28 V 

Output current:      

  max. 6,5 A 

Input voltage range:   

  90...264 VAC 

Input frequency:     

  47...63 Hz 

Effective power:      

  156 W 

Temperature range:    

  -20...+60 °C 

Storage temperature:   

  -40...+85 °C 

Dimensions: 

   

  ca. 190 x 190 x 190 mm  

 
Accessories:  

   

  Mast fixation for power[cube] 

(optional) 

   

 

Ident-Nr. 32.14966.030 000

 

 
 
Version:  

 

power[cube] „Wi-Fi“ 

 

  power[cube] incl. Data logger met[LOG] and Wi-Fi router 

 

   

Ident-Nr. 30.95800.115000

 

 

power[cube]

 

 

  power[cube] incl. Data logger met[LOG]  

 

   

Ident-Nr. 30.95800.015000

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Subject to change without notice.

 

 

BA_WiFi_powercube_metLOG_e (13.20) 

______________________________________________________________________________________ 

LAMBRECHT meteo GmbH 

 

 

Tel 

 

+49-(0)551-4958-0 

Friedlaender Weg 65-67 

 

 

Fax 

 

+49-(0)551-4958-312 

37085 Goettingen 

 

 

 

E-Mail   

[email protected] 

Germany 

 

 

 

 

Internet  

www.lambrecht.net 

Summary of Contents for power[cube] 30.95800.015000

Page 1: ...____________________________ ________________________________________________________________________________________________ 1 Manual power cube incl Data Logger met LOG Id No 30 95800 015000 power c...

Page 2: ...when it s delivered 2 Open Wi Fi settings at notebook PC or tablet choose Wi Fi net USR WIFI232 630_xxxx and connect xxxx refer to the last 4 sign of the MAC address of the Wi Fi module The network i...

Page 3: ...red to the customer English is set as standard In case Chinese is set the language can be changed via the link English which is located in the upper right side 4 Open the page Quick Configure via the...

Page 4: ...the page and restart the Wi Fi module by pressing Restart By doing the restart the changed configuration will work 11 After restart you reach the met LOG via the secured Wi Fi network with afore set...

Page 5: ...e Wi Fi is integrated Needed information MAC address Wi Fi module Destination WiFi name password destination WiFi Free IP address fix in destination Wi Fi for Wi Fi module Subnet mask of destination n...

Page 6: ...the Wi Fi network in which the power cube Wi Fi shall be integrated In the present example it is the network with SSID Name FB Lm 8 To save press the button Apply 9 Please make the following settings...

Page 7: ...ing via the corresponding link 12 Change the LAN settings LAN Setup of the Wi Fi module IP Address Default DHCP Gateway Free IP address fix in destination Wi Fi for Wi Fi module Subnet Mask Subnet mas...

Page 8: ...destination network via the Wi Fi module now it is shown by the command arp a in a generated list with the IP address of the Wi Fi module Search in the listed IP addresses for the IP address of the Wi...

Page 9: ...ser admin Password admin Wi Fi name Wi Fi module USR WIFI232 630_XXXX the name ends with the last 4 signs of the MAC address without or 1 Open the page Device Management via the corresponding link 2 B...

Page 10: ...put voltage range 90 264 VAC Input frequency 47 63 Hz Effective power 156 W Temperature range 20 60 C Storage temperature 40 85 C Dimensions ca 190 x 190 x 190 mm Accessories Mast fixation for power c...

Reviews: