Operating Instructions
Precipitation Sensor (15189 analog)

Dismounting of the protective covering

Loosening the screw (

fi

 g. 1) with the provided 3 mm allen key 

until the protective covering can be turned right to the stop 
position and take off upward then. 

Attention! 

In order to protect the tipping bucket the 

dirt spiral must be inserted in the collection funnel 
(

fi

 g. 2).

Assembly of the tipping bucket

To avoid damage to the tipping bucket during trans-
port, it is separately packed and should be inserted 
in the precipitation sensor on site only after mounting 
the gauge on the mast.
For the assembly 

fi

 rst you must remove the protec-

tive covering. 

Attention!

 When 

fi

 tting the tipping bucket, proceed 

with utmost caution so that the sharp edges of the 
tipping bucket are not damaged and the middle wall 
is not bent! 

During operation the tipping bucket lies on the precision buck-
et bearings. To reduce the friction, which is produced at one 
tipping, the bearings are made of abrasion-resistant delrin.
The mounted tipping bucket is secured against eventual 
changes of position by means of two plates.
To insert the tipping bucket, 

fi

 rst the relocatable locking plate 

C

  (

fi

 g. 3) must be pushed back.

Now insert the tipping bucket 

F

. Make sure that the magnet 

E

  

attached at the middle wall of the tipping bucket rests under 
the capsule with the embedded reed contact 

D

.

Finally the tipping bucket must be secured by pushing back 
the relocatable locking plate 

C

.

A:  Tipping bucket bearings
B:  Fixed locking plate  
C:  Relocatable locking plate 
D: Reed 

contact

E:  Magnet (here shown through inclination of the bucket)
F: Tipping 

bucket

Fig. 2

Fig. 3

3

E

F

D

C

Abb. 3

Summary of Contents for meteo 15189

Page 1: ...or gliding sum for the analogue output signals Exchangeable weighing tipping bucket system according to Joss Tognini overflow proof 2 cm tipping bucket 2 g water for precise precipitation measuring in...

Page 2: ...closed This signal can be sent as pulse or analog The bounce free linearised pulse output is permanently available parallel to an analog current or voltage output Thus an unproblematic integration in...

Page 3: ...roceed with utmost caution so that the sharp edges of the tipping bucket are not damaged and the middle wall is not bent During operation the tipping bucket lies on the precision buck et bearings To r...

Page 4: ...order to guarantee its proper operation since dirt accumulation may cause errors of measurement The time interval of cleaning depends on the local conditions The operational check of the sensor may be...

Page 5: ...eating Basic settings Fig 5 Unless otherwise agreed the precipitation sensor 15189 analog will be delivered with following basic settings Active pulse output linearised bounce free signal Measuring ra...

Page 6: ...b 1 J3 to select the required mode Pos 1 8 J4 J5 to switch on the respective analog output J6 to switch over the analog voltage output J12 to connect the switch output to the power supply for 2 wire c...

Page 7: ...s Precipitation Sensor 15189 analog Fig 9 Fig 10 Fig 11 Example 1 Fig 9 Active analog output 4 20 mA otherwise like basic setting Example 2 Fig 10 Active analog output 0 5 V otherwise like basic setti...

Page 8: ...e circuit Deactivated analog output Active pulse output linearised bounce free signal Current consumpt max 100 A typical 50 m Supply voltage 5 30 VDC Example 5 Fig 13 Low Power Mode PLC Interface Deac...

Page 9: ...ed range At exceeding of this final value a new sum mation starts i e the analog signal starts again on the low level sawtooth diagram 3 Gliding sum of precipitation At this operating mode the accumul...

Page 10: ...g cable 4 core sensor data logger L 7 m 00 15180 400 000 1518 S4 Stainless steel mast for con crete foundation 00 15180 800 000 1518 S8 Stainless steel mast for con crete foundation with base plate 32...

Reviews: