Technical data

(15189 analog) Version with 2 cm

bucket, unheated

Id-No. 00.15189.002 

050

Measuring principle:  Weighing tipping bucket designed acc. 

to Joss-Tognini

Range of application:   0...+70 °C - measuring
Measuring range: 

2 cm³ (2 g water) - volume of bucket
0...8 mm/min

Resolution: 0.1 

mm

Accuracy: 

± 2 % 

Dimensions: 

See dimensional drawing

Suitable for mounting:   Ø 60 mm
Weight: 

Approx. 4 kg

Standards: 

WMO-No. 8 • VDI 3786 Bl. 7
EN 50081/82 • VDE 0100

Analog outputs: 

0...20 mA = basic setting
4...20 mA • 0...5/10 V - selectable

Current consump.: 

 

40 mA  

Supply voltage: 

18...30 V

DC

 • max. load 600 

Ω

 

Pulse output for linearised, bounce-free output signal

At deactivated analog output:

Current consump.:  Max. 100 

μ

A · typical 50 

μ

Supply voltage: 

5...30 V

DC

 

Switch load: 

Max. 30 V

DC

/ max. 0.5 A - at pure ohm 

load

(15189 W4 analog) Version with 4 cm

bucket, unheated

Data like (15189 analog), but for very high precipitation intensity

Id-No. 00.15189.004 

050

Measuring range: 

4 cm³ (4 g water) - volume of bucket
0...16 mm/ min 

Resolution: 0.2 

mm 

(15189 H analog) Version with 2 cm

3

 bucket, heated

Data like (15189 analog) 00.15189.002 050, but in addition 
with controlled 2-circuit-heating:

Id-No. 00.15189.402 

050

Heating data: 

Electronic controlled, dual-circuit

Accuracy: 

4 °C ± 2 °C, controlled temperature
within a range of -20...+4 °C  

Heating power: 

80 W (funnel)

 

70 W (outlet/ tipping bucket)

Supply voltage: 

24 V

DC 

/ 150 W

Range of application:   -20...+70 °C (no icing, no snowdrift)

(15189 H W4 analog) Version with 4 cm

3

 bucket, heated

Date like (15189 W4 analog) 00.15189.004 050, but in addi-
tion with controlled 2-circuit-heating, like (15189 H analog)

Id-No. 00.15189.404 

050

General accessories:

32.15188.061 090  (15188 U61i) Connecting cable (4-core) 

sensor/ data logger, L = 7 m 

00.15180.400 000  (1518 S4) Stainless steel mast for con-

crete foundation  

00.15180.800 000  (1518 S8) Stainless steel mast for con-

crete foundation with base plate

32.15180.021 010   (1518 U21a) Bird protection ring
33.15180.049 000   (1518-49) Dirt spiral (spare part)

For heated versions:

00.14966.200 000  (1496 S62) Power supply unit
32.15188.061 020  (15188 U61b) Connecting cable

 

 

 

sensor/ power supply unit for mounting  

 

 

 

at the mast; L

1 m (4-core)

32.14622.220 000  (14622 S22) Holder for power supply  

 

 

 

unit on the mast

Services 

(see page 6):

97.15180.000 000  User-speci

fi

 c con

fi

 guration of the pre-

cipitation sensor

Safety instructions

This system is designed according to the state-of-the-art 
accepted safety regulations. However, please note the fol-
lowing rules:
1.   Before setting into operation, please read all appropriate 

manuals!

2.   Please take notice of internal and state-speci

fi

 c guidelines 

and/or rules for the prevention of accidents (e.g. the pro-
fessional association). If necessary ask your responsible 
safety representative.

3.   Use the system according to the manual’s regulations 

only.

4.  Always leave the manual at hand at the place of work of 

the system. 

5.   Use the system in technically correct conditions only! You 

have to eliminate in

fl

 uences immediately, which impair the 

security .

6.   Please note the loss of warranty and non-liability by unau-

thorized manipulation of the system. You need a written 
permission of the LAMBRECHT meteo GmbH for changes 
of system components. These activities must be operated 
by a quali

fi

 ed technician. 

7.   Prevent the ingress of liquids into the devices without 

permission.

Subject to change without notice. 

10

LAMBRECHT meteo GmbH 

 Tel 

+49-(0)551-4958-0

Friedländer Weg 65-67 

 Fax 

+49-(0)551-4958-312

37085 Göttingen 

  

E-Mail 

[email protected]

Germany 

  

Internet 

www.lambrecht.net

15189_Analog_b-de.indd      30.16

Quality System certified by DQS according to
DIN EN ISO 9001:2008 Reg. No. 003748 QM08

Summary of Contents for meteo 15189

Page 1: ...or gliding sum for the analogue output signals Exchangeable weighing tipping bucket system according to Joss Tognini overflow proof 2 cm tipping bucket 2 g water for precise precipitation measuring in...

Page 2: ...closed This signal can be sent as pulse or analog The bounce free linearised pulse output is permanently available parallel to an analog current or voltage output Thus an unproblematic integration in...

Page 3: ...roceed with utmost caution so that the sharp edges of the tipping bucket are not damaged and the middle wall is not bent During operation the tipping bucket lies on the precision buck et bearings To r...

Page 4: ...order to guarantee its proper operation since dirt accumulation may cause errors of measurement The time interval of cleaning depends on the local conditions The operational check of the sensor may be...

Page 5: ...eating Basic settings Fig 5 Unless otherwise agreed the precipitation sensor 15189 analog will be delivered with following basic settings Active pulse output linearised bounce free signal Measuring ra...

Page 6: ...b 1 J3 to select the required mode Pos 1 8 J4 J5 to switch on the respective analog output J6 to switch over the analog voltage output J12 to connect the switch output to the power supply for 2 wire c...

Page 7: ...s Precipitation Sensor 15189 analog Fig 9 Fig 10 Fig 11 Example 1 Fig 9 Active analog output 4 20 mA otherwise like basic setting Example 2 Fig 10 Active analog output 0 5 V otherwise like basic setti...

Page 8: ...e circuit Deactivated analog output Active pulse output linearised bounce free signal Current consumpt max 100 A typical 50 m Supply voltage 5 30 VDC Example 5 Fig 13 Low Power Mode PLC Interface Deac...

Page 9: ...ed range At exceeding of this final value a new sum mation starts i e the analog signal starts again on the low level sawtooth diagram 3 Gliding sum of precipitation At this operating mode the accumul...

Page 10: ...g cable 4 core sensor data logger L 7 m 00 15180 400 000 1518 S4 Stainless steel mast for con crete foundation 00 15180 800 000 1518 S8 Stainless steel mast for con crete foundation with base plate 32...

Reviews: