Heating power adjustment
To adjust the heating power, switch the boiler to TEST mode (see sec. 4.1). Press the
heating buttons detail 3 - fig. 1 to increase or decrease the power (min. = 00 - max. =
100). Press the
reset
button within 5 seconds and the max. power will remain that just
set. Exit TEST mode (see sec. 4.1).
Configuration Menu
Press the DHW buttons together for 10 seconds to access the configuration Menu. 7 pa-
rameters are available, indicated by the letter "b", which are not modifiable from Remote
Timer Control.
Press the Heating buttons to scroll the list of parameters in increasing or decreasing or-
der. Press the DHW buttons to view or modify the value of a parameter: the modification
will be automatically saved.
Notes:
1.
Parameters with more than one description vary their function and/or range in rela-
tion to the setting of the parameter given in brackets.
2.
Parameters with more than one description are reset to the default value if the pa-
rameter given in brackets is modified.
To exit the configuration Menu press the DHW buttons together for 10 seconds, or exiting
occurs automatically after 2 minutes.
fig. 10 - Gas valve
A
- Upstream pressure point
B
- Downstream pressure point
I
- Gas valve electrical connection
R
- Gas outlet
S
- Gas inlet
fig. 11 - Gas valve connection
TYPE SGV100
Pi max 65 mbar
24 Vdc - class B+A
Contents Description
Range
Default
TAURA D MCA
b01
Gas type selection
0 = Natural gas
0=Natural Gas
0=Natural Gas
1 = LPG
b02
Boiler type selec-
tion
1 = Bithermal instantaneous
1=Bithermal
instantaneous
1=Bithermal
instantaneous
2 = Monothermal instantaneous
3 = Heating only (3-way valve)
4 = Heating only (circulating pump)
b03
Combustion
chamber type
selection
0 = Sealed Chamber combustion control
(without fume pressure switch)
0=Sealed
Chamber with
combustion con-
trol
1=Open Cham-
ber
(with fume ther-
mostat)
1 = Open Chamber (with fume thermostat)
2 = Sealed Chamber (with fume pressure
switch)
3 = Sealed Chamber combustion control
(with fume thermostat on recuperator)
4 = Low-NOx Sealed Chamber combustion
control (without fume pressure switch)
5 = Open Chamber (with fume thermostat)
b04
Primary
Exchanger type
selection
(b03=0)
0 = Flat
0=Flat
0=Flat
1 = Omega
2 = --
No effect on
adjustment
(b03=1)
--
0
No effect on
adjustment
(b03=2)
--
0
Primary
Exchanger type
selection
(b03=3)
0 = Flat
0=Flat
1 = Omega
2 = --
No effect on
adjustment
(b03=4)
--
0
No effect on
adjustment
(b03=5)
--
0
R
B
I
A
S
~ 65
Ω
~ 24
Ω
b05
Relay card LC32
operation selec-
tion (b02=1)
0 = External gas valve
0=External gas
valve
0=External gas
valve
1 = System filling solenoid valve
2 = Solar 3-way
No effect on
adjustment
(b02=2)
--
0
No effect on
adjustment
(b02=3)
--
0
No effect on
adjustment
(b02=4)
--
0
b06
Mains Voltage
Frequency
0=50Hz
0=50Hz
0=50Hz
1=60Hz
b07
Comfort burner on
time
(b02=1)
0-20 seconds
5 seconds
5 seconds
No effect on
adjustment
(b02=2)
--
5
No effect on
adjustment
(b02=3)
--
5
No effect on
adjustment
(b02=4)
--
5
Contents Description
Range
Default
TAURA D MCA