NINFA 24 MCS
46
GB
cod. 3540F611 - 05/2007 (Rev. 00)
Connection with coaxial pipes
Fit the concentric bend, positioning it in the required direction, insert the seal on it and install the diaphragm (when nec-
essary). Fit the fume exhaust and inlet pipes, respecting the measurements given in the respective installation diagram.
The fume exhaust must be kept sloping slightly towards the outside.
Max. length CONCENTRIC EXHAUST 3 m + bend
fig. 22
A
Exhaust
B
Fume diaphragm
Connection with separate pipes
1. Establish the complete layout of the system of split flues, including accessories and outlet terminals.
2. Consult the following table and identify the losses in m
eq
of every component, according to the installation position.
3. Check that the sum total of losses is less than or equal to the maximum permissible value: 35 m
eq
.
Accessories and pipe losses tables
Losses m
eq
Component
Drawing
Inlet
Vertical exhaust
Horizontal exhaust
Ø80 accessories
Ø80 male-female pipe
1
1
2
Ø80 45° bend
1.2
2.2
Ø80 90° male-female bend
1.5
2.5
100 Max. 3000
235
Ø100
105
720
100
Max. 3000
230
320
B
A
420
Summary of Contents for NINFA 24 MCS
Page 155: ...NINFA 24 MCS 155 EL cod 3540F611 05 2007 Rev 00 5 1 9 1 2 6 1 9 1 3 Comfort Comfort 6 1 9 1 4...
Page 157: ...NINFA 24 MCS 157 EL cod 3540F611 05 2007 Rev 00 3 1 8 1 4 3 1 9 3 1 1 1 30 C 85 C 45 C 10...
Page 172: ...NINFA 24 MCS 172 EL cod 3540F611 05 2007 Rev 00 3 2 B sez 4 4 sez 1 3 sez 4 4 3 3 1 bar A...
Page 175: ...NINFA 24 MCS 175 EL cod 3540F611 05 2007 Rev 00 F37 F39 A41 F42 F43 H2O F50...
Page 182: ......
Page 183: ......