NINFA 24 MCS
39
GB
cod. 3540F611 - 05/2007 (Rev. 00)
Compensation curve and curve shift
Turn the selector (detail 3 - fig. 1) to RESET for 5 seconds and then to
(winter) or
(summer) and “CU” will be
displayed.
Operate the DHW knob (detail 2 - fig. 1) to adjust the required curve from 1 to 10 according to the characteristic (fig. 14).
By setting the curve to 0 sliding temperature adjustment is deactivated.
fig. 12 - Compensation curve
Turn the selector (detail 3 - fig. 1) to RESET for 1 second and then to
(winter) or
(summer) to exit compensation
curve setting and “CU” will be displayed again.
Turn the heating knob (detail 1 - fig. 1) clockwise and “OF” will be displayed.
Operate the DHW knob (detail 2 - fig. 1) to adjust the curve shift (fig. 15).
fig. 13 - Parallel curve shift
Turn the selector (detail 3 - fig. 1) to RESET for 5 seconds and then to
(winter) or
(summer) to exit parallel curve
adjustment mode.