CLEANING THE BOILER
Contact a qualified technician to clean the boiler.
Use a damp cloth to remove dust from the shell.
Disconnect power supply before performing this operation.
Do not use detergents or solvents. For resistant spots, if a damp cloth is not sufficient, use alcohol.
Check the position of the thermostats and supply the boiler again.
FUME THERMOSTAT
RESTARTING THE BOILER
When the fume thermostat triggers, the warning lamp at the “clogged chimney” symbol on the control panel
lights up.
To restore the boiler operation, do the following:
- disconnect the plug from the mains
- lift the boiler shell cover to access the thermostat
- remove the plastic cap exiting from the instrument panel (No. 13)
- press the red button
- remount the plastic cap and reposition the shell cover
- connect the plug
Warning: should this operation be repeated more than three times, contact a qualified technician, who will
check the thermostat efficiency. If so, the chimney should be checked by the installer. If the chimney draught
is not sufficient, it must be adjusted.
WARNING
: The fume thermostat has been pre-regulated and its sensitive element has been arranged so that
the device triggers within the maximum times set by the regulations. It is
absolutely forbidden
to change the
bulb position and electric connections. It is also forbidden to replace the thermostat with a non-original one.