44
Calendar override
Information
The calendar override can be set from 0 (OFF) to 99 days.
Information
If no regeneration occurred during this programmed interval of day (calendar override),
the controller will automatically start a regeneration.
Information
This type of regeneration is carried out at the regeneration time even on non-enabled
days.
Information
This option is displayed only if
SH
(regeneration mode) is set to 1, 2 or 4.
Set the calendar override.
A
Use
and
to set the calendar override.
B
Press
to confirm and go to the next parameter.
Main electrical frequency
Set the main electrical frequency to 50 or 60 Hz.
A
Use
and
to set the frequency.
B
Press
to confirm and go to the next parameter.
Manual opening of the brine valve
Information
When the brine valve opens and closes, a mechanical movement appears on the display.
When the valve is completely open, the display shows bMON and when the valve is
completely closed, the display shows bMOF.
Caution
When this command is activated, the user/installer has full control of the brine valve.
Warning
Lamborghini Caloreclima shall not be held liable for any damage caused by the
incorrect use of this command by the user/installer.
A
Press
to open the brine valve.
B
Press
to close the brine valve.
C
Press
to confirm and go to the next parameter.