BIO CO MPUR ITY SYSTEM
MULTIMOD E
ORARIO
ORA DI RIG.
GIORNO DI RIG.
VOLU ME
TEMPO
VOLU ME
VOL. RIMANENTE
PROGRAMMA
AVANZAMENTO
VOLUME/ORA
RIG. MANUALE
RESET
CALORECLIMA
A
D
B
E
C
F
TIMER MULTIMODE PLUS
The electronic circuit is powered at 12 V (AC) 8A and the
TIMER is supplied with an external power device so that it may
be connected directly to the mains (220 V).
Even where the power is switched off (max. 3 months) the
TIMER keeps the time stored. The keys on the TIMER must be
pressed for between 0.6 and 1.2 seconds. During the
regeneration stage (both automatic and manual), the DISPLAY
shows the seconds of rotation of the motor drive as they
decrease, plus those of the CAM and the minutes of stop for the
single cycles (1C - backwash, 2C regeneration, 3C slow rinse,
4C rapid rinse).
During a regeneration it is not possible to perform any other
programming.
TIME
}
If lit, this indicates that the TIMER is operating on TIME.
VOLUME
TIME
}
If both lit, this indicates that the TIMER is operating on TIME-VOLUME.
VOLUME
TIME
}
If lit, this indicates that the TIMER is operating on VOLUME.
VOLUME
KEYBOARD FUNCTIONS
A
DAY-TIME
- To program the day time
- To program the regeneration cycles
B
PROGRAM
- To program the various functions
- To program the regeneration cycles
C
ADVANCE
- Increases the figures seen on the DISPLAY
- Selects the functioning: TIME, VOLUME, TIME-VOLUME
D
VOL/TIME
- Displays the figure of the water volume or the day time
E
MAN. REG.
- Performs immediate regeneration
F
RESET
- Interrupts a regeneration set off by mistake