48
To gain access to the PHASE number press the MODE button once (an indicator light to the right of the 1
st
figure
comes on). Press STEP to display all the available PHASES.
LIST OF PARAMETERS INDICATED BY 1
st
FIGURE ON DISPLAY (Values can be adjusted by the user).
2
Phase N
°
Parameter
Value range
00 =domestic hot water excluded
01 = 5
°
C hyst pump
continuously on Hot water
02 = 5
°
C hysteresis
03 = 10
°
C hysteresis
04 = 20
°
C hysteresis
05 = 30
°
C hysteresis
1
Hot water temperature
from 40 to 65
°
C
02
Hot water system
00 = heating disabled
01 = heating enabled
02 = heating enabled, pump
running continuously
01
3
Heating
4
80
settable minimum 55
°
C
Water delivery temperature
from 20 to 90
°
C
50
Default
settings
To exit the PHASE list press twice.
Example:
indicator light
Step
N
°
display
Parameter value
display
65
CIRCUITO HIDRÁULICO
DESCRIPCIÓN
A
Gas
B
Entrada agua fría
C
Salida agua caliente sanitaria
D
Ida instalación
E
Retorno instalación
1
Purgador del aire
2
Electrodo de control
3
Conexión inyector
4
Transformador de encendido
5
Electrodos de encendido
6
Sonda de control ida instalación
7
Sonda de control retorno instalación
8
Ventilador
9
Presóstato aire
10
Válvula gas
11
Vaso de expansión
12
Circulador
13
Sonda circ. sanitario
14
Válvula 3 vías
15
Calentador de agua caliente sanitaria
16
Grifo de llenado
17
Válvula de seguridad
18
Hidrómetro
19
Presóstato falta de agua
Summary of Contents for BANOX 24 MCS W TOP U/IT