background image

INTRODUCTION  

 

 ENGLISH 

AND SAFETY NORMS

             

 

 

INTRODUCTION 

 

The machine Minibar is an industrial glass-washing machine. 

The machine is in compliance with the

 European Norms 89/336/CEE 

for the radio noises. 

According to EEC directive nr.23 of 19/02/1973 and the law of actuation nr.791 of 18/10/1987, our 
appliances are built-up according to the good technique norms in force in Italy and abroad. 

Noise level of the machine, less than 

70 dB(A)

 

PRELIMINARY OBSERVATION 

 
Carefully read the instructions reported in the present user manual, as it gives important indications about 
safety of installation, operation and maintenance: 

carefully keep the present manual for further consultations; 

the illustrations and drawings showing the machine are intended for general reference only and are not 
necessarily accurate in every particular; 

the dimensions and characteristics of the machine, given in this Manual, are not to be considered 
binding and may be changed without prior notice; 

having removed the packing material, check that all the equipment is present. If there is any doubt, do 
not use it and contact qualified personnel. The packing elements (plastic bags, nails, etc.) should be 
kept away from children, because they are dangerous. 

 

GENERAL SAFETY REGULATIONS 

 
This safety code has been compiled in your interest. Strict adherence to these rules will reduce the risks of 
injury both to yourself and to others; 
Personnel working with this machine must adhere strictly to all statutory safety regulations as well as the 
specific rules listed below. Failure to do so may result in personal injury and damage to the machine; 

Do not attempt  to move, install, set up or operate with this machine until you have read and fully 
understood this Manual. If doubt persists, ask your supervisor; 

never leave tools, parts or other loose material on or in the machine; 

Before switching the equipment on, make sure that the model plate data conform to those of the 
electrical and water distribution network; 

remember that even with the mains isolator in the “OFF” position, the incoming cables are still live; 

-  

Before starting machine or cycle, after any maintenance or repair work, make sure all protective are 
correctly installed; 

be vigilant at all times, remember that your safety and that of your fellow workers depend on you; 

when moving or lifting the machine, care must be taken to comply with all the relevant regulations 
governing such operations; 

installation should be carried out by qualified personnel according to the manufacturer's instructions; 

this equipment should be destined to the use which it has been conceived for. Any other application 
should be considered improper and consequently dangerous; 

the  equipment should only be used by personnel trained for its use. 

 

SPECIAL SAFETY REGULATIONS 

 

adjustement  and repairs must be carried out only by qualified personnel. Repair carried out by 
unskilled personnel may be dangerous; 

-  

perfect washing-up results as regards hygiene and a correct operation of the washing machine can be 
assured only in case the instructions reported in the present handbook are carefully followed; 

the machine must be used only by authorized personnel which must comply with sanitary measures; 

-  

do not leave the machine in environment with lower temperatures than 0°C; 

-

 

the machine protection degree is IP21, therefore it should not be washed with direct high pressure 
jets of water. 

 
 
 

Summary of Contents for Minibar

Page 1: ...hwashing machines EN 292 2 1992 Part 1 PART 2 Sicurezza del macchinario Concetti fondamentali Principi generali progettazione Specifiche e principi tecnici Safety of machinery Basic concepts General p...

Page 2: ...c compatibility EMC Part 3 2 Limits Limits for harmonic current emissions equipment input current 16 A per phase EN 61000 3 2 2000 Compatibilit elettromagnetica EMC Parte 3 2 Limiti Limiti per le emis...

Page 3: ...le Bureau National des producteurs de AEE Appareillages Electriques et Electroniques partir du 18 02 2008 avec le num ro IT08020000000617 WASTE OF ELECTRICAL AND ELECTRONIC EQUIPMENT DIRECTIVE WEEE R...

Page 4: ...idange branchement lectrique pag 33 Sch ma branchements pag 39 Sch ma r gulations pag 40 Sch ma lectrique pag 41 Composants pag 42 Donn es techniques pag 43 CONTENTS ENGLISH General norms pag 05 Intro...

Page 5: ...s le manuel y compris les recommandations et les suggestions Lisez aussi les conditions de vente y compris celles qui limitent la garantie GENERAL NORMS ENGLISH Thank You for purchasing our Glasswashi...

Page 6: ...au point ou actionner la machine avant d avoir lu et avoir pleinement compris le contenu du manuel En cas de doutes s adresser son sup rieur Ne jamais laisser d ustensiles objets ou autre mat riel su...

Page 7: ...to the machine Do not attempt to move install set up or operate with this machine until you have read and fully understood this Manual If doubt persists ask your supervisor never leave tools parts or...

Page 8: ...ngelement Tankheizung Risciacquo inferiore rotanteinacciaio inox cono 90 Rin ageinf rieur rotatif enacier inoxydable c ne 90 Stainless steel Lower rotating rinsing 90 Scarico vasca Vidange cuve Tank d...

Page 9: ...NORME PER L UTENTE INSTRUCTIONS POUR L UTILISATEUR INSTRUCTIONS FOR THE USER AUFSTELLUNGSANLEITUNG F R DEN BENUTZER...

Page 10: ...witch Hauptschalter Pulsante ciclo Bouton cycle Cycle pushbutton Programmdrucktaste Lampada linea Lampe indicatrice de ligne Main switch lamp Netzkontrollampe Lampada ciclo Lampe indicatrice de cycle...

Page 11: ...appareils automatiques pour le dosage du d tersif controler la pr sence de ce d tersif dans les r cipients B Introduire la vaisselle dans les paniers appropri s apr s avoir enlev tous les restes soli...

Page 12: ...chlore actifs sp cifiques pour les lave vaisselle industriels fabriqu s par des firmes de bonne renomm e La concentration moyenne des d tersifs liquides doit tre de 1 5 2 5 g litre La concentration m...

Page 13: ...age ne soient pas bouch es Remettre les pi ces enlev es dans leurs emplacements Nettoyer l ext rieur de la machine au moyen d une ponge humide ne pas utiliser de jets d eau car en autre d tre dangere...

Page 14: ...t et soigneusement les surfaces avec un chiffon humide on pourra utiliser de l eau avec du savon ou bien les d tergents ordinaires pourvu qu ils ne contiennent pas de substances abrasives ou base de c...

Page 15: ...hat the detergent is in its container B Place the dishes in the basket minding to previously remove all solid waste and fat Do not overload baskets dishes must not be placed one upon the other water m...

Page 16: ...will not deposit on the tank bottom RINSING ADDITIVES To grant a perfect rinsing a quick drying and to avoid calcareous sediments on glasses and cups you must add a surfactant on water Brightener You...

Page 17: ...heir housings Check and clean the washing and the rinsing jets Clean the outer surface of the machine by using a wet sponge don t use water jets because besides being dangerous they could damage the e...

Page 18: ...erior panelling upper tops tanks etc Comply with the following instructions when cleaning and servicing parts in stainless steel Ordinary daily maintenance Carefully and frequently clean the surfaces...

Page 19: ...ur d cline toute responsabilit en cas d interventions effectu es par du personnel non qualifi INSTRUCTIONS FOR THE INSTALLER The following instructions are addressed to a qualified personnel the only...

Page 20: ...ettrica Branchement lectrique Electric input Netzanschlu Drain Ablauf 3 4 G 32 mm 1 1 4 G Scarico acqua Evacuation Eau A Altezza massima per scarico a muro Hauteur maximale pour vidange mur Maximum he...

Page 21: ...faut utiliser un c ble d alimentation du type H07RN F qui en plus a une section nominale ad quate Pour un choix correct de la section nominale du c ble conseiller le tableau suivant Surface Absorption...

Page 22: ...ns de d sincrustation et augmenter la concentration de d tersif Il est conseill d utiliser seulement des adoucisseurs change ionique Osmose inverse les proc d s bas s aux champs lectriques ou aux radi...

Page 23: ...st also be provided with a proper ground lead in accordance with the existings norms The electric cable must be of the following type H07RN F For the right choice of the cross section area refer to th...

Page 24: ...is advisable to install a Booster Pump Hardness between 7 2 and 12 5 French If the hardness values are higher than those mentioned above it is advisable to install a water softener WORK TEMPERATURES W...

Page 25: ...ermostat Pompa Pompe Pump Pumpe Liberi Libres Free Frei 12 14 13 7 ROSSO ROUGE RED ROT 10 A B D G M C F H E I L N T4 T2 T3 T1 A B C D E F G L H M I N 1 cc sec 3 6Lit h Cod 0500060 Um die Reinigungsmit...

Page 26: ...isciacquo Entr e du produit de rin age Rinse aid inlet Nachsp lmitteldosierger t SCHEMA REGOLAZIONI SCHEMA REGULATION REGULATION SCHEME EICHUNG A B A Termostati Lavaggio Thermostat Lavage Wash thermos...

Page 27: ...Dos IN Fc R1 R2 LS LS2 LS4 MT1 MT4 CP CT1 CT2 CT3 M T1 T4 PM EV1 PC Ad Dos SCHEMA ELETTRICO SCHALTSCHEMA SCHEMA ELECTRIQUE WIRING DIAGRAM Main switch Limit switch Boiler elements Tank elements Main s...

Page 28: ...2 R1 PM Cd EV1 PC IN T4 T2 T3 T1 1 2 3 4 5 6 7 10 8 11 9 12 1 3 2 Morsetti KOMPONENTEN COMPOSANTS COMPONENTS COMPONENTI CASSETTA QUADRO COMANDO CONTROL BOARD BOITE DE CONTROLE SCHALTTAFEL BASAMENTO SO...

Page 29: ......

Reviews: