lamber Minibar Instructions For The User Download Page 17

23 

CLEANING AND PREVENTIVE 
MAINTENANCE 

 

PRECAUTION AND CLEANING 
INSTRUCTIONS 

 

IMPORTANT

: Before carrying out the 

cleaning and maintenance operations, 
disconnect the equipment from the mains 
power supply: 

 

 

-  

high temperatures can be reached inside 
the machine (90°C). After power supply has 
been removed, wait until the machine has 
reached the room temperature, before 
working on it. 

 

The machine protection degree is IP21, 
therefore it should not be washed with direct 
high pressure jets of water. 

 

Never leave tools, parts or other loose 
material on or in the machine. 

 
-  

Before starting machine or cycle, after any 
maintenance or repair work, make sure all 
protective are correctly installed. 

 
 

DAILY MAINTENANCE 

 

-   

Disconnect the machine with pushbutton 
"A"; 

Lift   the   overflow  pipe and let the water 

 

drain out of the tank; 

Wash thoroughly the tank and  the filter 

 

housing to remove all the impurities; 

Take the filters and clean them under 
running water; 

-  

Re-assemble the overflow   pipe   and the 

 

filters in their housings; 

Check and  clean the washing and the 
rinsing jets; 

Clean the outer surface of the machine by 
using a wet sponge; don't use water jets 
because, besides being dangerous they 
could damage the electrical parts; don't 
use abrasive detergents; 

When the machine is to remain idle  for a 

 

long time, drain all  the water   from    the 

 

boiler   and    from   the   electropump. 

 

Also leave the wash  tank open. 

 

NEVER WASH THE EXTERNAL PART  OF 
THE MACHINE WITH A WATER JET 
 
 
 
 

 

POSSIBLE TROUBLES - CAUSES - SOLUTIONS 

 

PROBLEMS 

CAUSES 

SOLUTIONS 

 
The machine doesn't catch 

Main switch is switched off 

Turn ON the main switch 

 
The water doesn't go in 

Water cock closed, 

Open water cock, 

 
 

The Overflow is not in its place 

Reassemble the Overflow in its 

 

 

place 

 
Insufficient Washing 

Wrong detergent or dosage  

Use anti-foam detergent in the 

 

Insufficient, 

right dosage and never with  

 

 

cold water, 

 
 

Low temperature in the tank, 

Wait untill the water gets hot, 

 
 

Dirty wash filter 

Clean the filter 

 
Insufficient Rinsing 

Rinsing nozzles blocked, 

Unscrew and clean nozzles  

 

 

under running water, 

 
 

Hydraulic pressure lower than 

Wait until the pressure is on or 

 

1 bar - 100 kPa 

buy a booster pump 

 

CAUTION! FOR ANY OTHER TROUBLE, CALL SERVICE 

 

Summary of Contents for Minibar

Page 1: ...hwashing machines EN 292 2 1992 Part 1 PART 2 Sicurezza del macchinario Concetti fondamentali Principi generali progettazione Specifiche e principi tecnici Safety of machinery Basic concepts General p...

Page 2: ...c compatibility EMC Part 3 2 Limits Limits for harmonic current emissions equipment input current 16 A per phase EN 61000 3 2 2000 Compatibilit elettromagnetica EMC Parte 3 2 Limiti Limiti per le emis...

Page 3: ...le Bureau National des producteurs de AEE Appareillages Electriques et Electroniques partir du 18 02 2008 avec le num ro IT08020000000617 WASTE OF ELECTRICAL AND ELECTRONIC EQUIPMENT DIRECTIVE WEEE R...

Page 4: ...idange branchement lectrique pag 33 Sch ma branchements pag 39 Sch ma r gulations pag 40 Sch ma lectrique pag 41 Composants pag 42 Donn es techniques pag 43 CONTENTS ENGLISH General norms pag 05 Intro...

Page 5: ...s le manuel y compris les recommandations et les suggestions Lisez aussi les conditions de vente y compris celles qui limitent la garantie GENERAL NORMS ENGLISH Thank You for purchasing our Glasswashi...

Page 6: ...au point ou actionner la machine avant d avoir lu et avoir pleinement compris le contenu du manuel En cas de doutes s adresser son sup rieur Ne jamais laisser d ustensiles objets ou autre mat riel su...

Page 7: ...to the machine Do not attempt to move install set up or operate with this machine until you have read and fully understood this Manual If doubt persists ask your supervisor never leave tools parts or...

Page 8: ...ngelement Tankheizung Risciacquo inferiore rotanteinacciaio inox cono 90 Rin ageinf rieur rotatif enacier inoxydable c ne 90 Stainless steel Lower rotating rinsing 90 Scarico vasca Vidange cuve Tank d...

Page 9: ...NORME PER L UTENTE INSTRUCTIONS POUR L UTILISATEUR INSTRUCTIONS FOR THE USER AUFSTELLUNGSANLEITUNG F R DEN BENUTZER...

Page 10: ...witch Hauptschalter Pulsante ciclo Bouton cycle Cycle pushbutton Programmdrucktaste Lampada linea Lampe indicatrice de ligne Main switch lamp Netzkontrollampe Lampada ciclo Lampe indicatrice de cycle...

Page 11: ...appareils automatiques pour le dosage du d tersif controler la pr sence de ce d tersif dans les r cipients B Introduire la vaisselle dans les paniers appropri s apr s avoir enlev tous les restes soli...

Page 12: ...chlore actifs sp cifiques pour les lave vaisselle industriels fabriqu s par des firmes de bonne renomm e La concentration moyenne des d tersifs liquides doit tre de 1 5 2 5 g litre La concentration m...

Page 13: ...age ne soient pas bouch es Remettre les pi ces enlev es dans leurs emplacements Nettoyer l ext rieur de la machine au moyen d une ponge humide ne pas utiliser de jets d eau car en autre d tre dangere...

Page 14: ...t et soigneusement les surfaces avec un chiffon humide on pourra utiliser de l eau avec du savon ou bien les d tergents ordinaires pourvu qu ils ne contiennent pas de substances abrasives ou base de c...

Page 15: ...hat the detergent is in its container B Place the dishes in the basket minding to previously remove all solid waste and fat Do not overload baskets dishes must not be placed one upon the other water m...

Page 16: ...will not deposit on the tank bottom RINSING ADDITIVES To grant a perfect rinsing a quick drying and to avoid calcareous sediments on glasses and cups you must add a surfactant on water Brightener You...

Page 17: ...heir housings Check and clean the washing and the rinsing jets Clean the outer surface of the machine by using a wet sponge don t use water jets because besides being dangerous they could damage the e...

Page 18: ...erior panelling upper tops tanks etc Comply with the following instructions when cleaning and servicing parts in stainless steel Ordinary daily maintenance Carefully and frequently clean the surfaces...

Page 19: ...ur d cline toute responsabilit en cas d interventions effectu es par du personnel non qualifi INSTRUCTIONS FOR THE INSTALLER The following instructions are addressed to a qualified personnel the only...

Page 20: ...ettrica Branchement lectrique Electric input Netzanschlu Drain Ablauf 3 4 G 32 mm 1 1 4 G Scarico acqua Evacuation Eau A Altezza massima per scarico a muro Hauteur maximale pour vidange mur Maximum he...

Page 21: ...faut utiliser un c ble d alimentation du type H07RN F qui en plus a une section nominale ad quate Pour un choix correct de la section nominale du c ble conseiller le tableau suivant Surface Absorption...

Page 22: ...ns de d sincrustation et augmenter la concentration de d tersif Il est conseill d utiliser seulement des adoucisseurs change ionique Osmose inverse les proc d s bas s aux champs lectriques ou aux radi...

Page 23: ...st also be provided with a proper ground lead in accordance with the existings norms The electric cable must be of the following type H07RN F For the right choice of the cross section area refer to th...

Page 24: ...is advisable to install a Booster Pump Hardness between 7 2 and 12 5 French If the hardness values are higher than those mentioned above it is advisable to install a water softener WORK TEMPERATURES W...

Page 25: ...ermostat Pompa Pompe Pump Pumpe Liberi Libres Free Frei 12 14 13 7 ROSSO ROUGE RED ROT 10 A B D G M C F H E I L N T4 T2 T3 T1 A B C D E F G L H M I N 1 cc sec 3 6Lit h Cod 0500060 Um die Reinigungsmit...

Page 26: ...isciacquo Entr e du produit de rin age Rinse aid inlet Nachsp lmitteldosierger t SCHEMA REGOLAZIONI SCHEMA REGULATION REGULATION SCHEME EICHUNG A B A Termostati Lavaggio Thermostat Lavage Wash thermos...

Page 27: ...Dos IN Fc R1 R2 LS LS2 LS4 MT1 MT4 CP CT1 CT2 CT3 M T1 T4 PM EV1 PC Ad Dos SCHEMA ELETTRICO SCHALTSCHEMA SCHEMA ELECTRIQUE WIRING DIAGRAM Main switch Limit switch Boiler elements Tank elements Main s...

Page 28: ...2 R1 PM Cd EV1 PC IN T4 T2 T3 T1 1 2 3 4 5 6 7 10 8 11 9 12 1 3 2 Morsetti KOMPONENTEN COMPOSANTS COMPONENTS COMPONENTI CASSETTA QUADRO COMANDO CONTROL BOARD BOITE DE CONTROLE SCHALTTAFEL BASAMENTO SO...

Page 29: ......

Reviews: