28
The manufacturer declines any
responsibility for any damages caused
by lack of an effective ground
installation.
Emergency pushbuttons:
The machine is also equipped with
emergency pushbuttons located by the
inlet and outlet tables of the machine.
WATER CONNECTIONS
Carefully comply with any national or
regional regulations in force.
Hot water supply
Arrange a gate valve in an easily
accessible place, with a tap having a
3/4"gas thread spout at its end and
connect to the water inlet valve (fig.1)
-
temperatur
:
55°C
,
-
Dynamic Pressure
2÷4 bar (200÷400
kPa),
-
Hardness
between
7,2 and 12,5 °F
N.B.:
Each machine is equipped with a
pressure reducer. In order to obtain an
excellent rinsing, it shall be calibrated
according to the data reported on the plate
located in connection with the reducer
itself.
Cold water supply
This connection is required only for
machine with
pre-wash
and any other
dishwasher equipped with
steam
condenser or regenerator
.
Water shall be supplied at a temperature
ranging from 10-15°C and at a dynamic
pressure of 2÷4 bar (200÷400 kPa).
WATER DRAINING
Reachable from the machine front side
after opening the front panel (to do this
turn the two front screws out);
Arrange a discharge at floor level
provided with siphon and connect to the
floor drain by means of a hose provided
with an adequate inclination. Make sure
the drain hose is not choked in any way.
Make sure the drain hose is resistant to a
temperature of 70 °C.
Carefully comply with any national or
regional regulations in force.