27
POSITIONING
During the installation provide a good
leveling of the machine in order to allow it
to work properly (doors, basket
transport). The setting requires the ruling
of the supporting feet.
After removing the front panels, place the
machine over the connections.
Provide for the connections.
The machine shall also be equipped with
detergent and brightener dispensers,
which shall be supplied by the
manufacturer of these products.
To connect the dispensers there are four
light blue terminals
, marked with special
labels, which are under tension when the
pump is working. To avoid damages to the
electrical components it is compulsory to
use these terminals and avoid movable
connections in other points of the plant.
Terminal voltage corresponds to line
voltage.
ELECTRICAL CONNECTION
Before connecting the machine,
check to make sure the voltage
outlet of the mains is the same as
the voltage specified on the data
plate of the machine.
It is also necessary to check that the
counter, the mains and the intake are
adequately dimensioned to withstand the
required maximum load.
A main switch must be installed between
the mains and the machine. This safety
measure also requires that the minimum
distance between the switch contacts is
at least 3 mm and the disconnection on
all poles according to
EN 60204 (VDE
113)
.
The mains must be wired to be able to
handle the current drawn by the
machine.The system must also be
provided with a proper ground lead in
accordance with the existings norms. The
electric cable must be of the following
type
H07RN-F
.
For a correct selection of the cable rated
cross-section refer to the data reported
on the product data plate.
The cable cross-section shall not be
inferior to the one indicated in the
“Technical data and description” reported
in the first page of the present manual.
The cable shall be connected to the
isolator IA1
and to the adjacent yellow-
green terminal, it shall be made passed
and stopped by means of the apposite
cable grip.
It is necessary to connect the equipment
to an effective ground installation, as
specified by the electrical safety
regulations in force.
Chack that this basic requirement is
complied with and, in case of doubt, ask
for a careful check of the installation by a
qualified personal.
In addition, the equipment shall be part of
an equipotential system, the
effectiveness of which should be checked
according to the regulations in force.
The connection should be made at the
screw marked by the respective label
located on the equipment back side ( ).
It is recommended to make the electric
line be checked by your own designer.
THE MACHINE SHALL BE
CONNECTED WITH AN EFFECTIVE
GROUND CLAMP.