background image

Lambda Labs - Professional Acoustics                                                                                                                                           KW-18 Amplifier Rack Manual

1. Safety

 

This manual contains essential information on product safety, installation and usage. Read this manual carefully in order to 
become familiar with the operation and usage of the product/s. Read this manual carefully BEFORE operating the product/s 
for the first time! Read the IMPORTANT GENERAL SAFETY REGULATIONS you can find on the next pages! 

• Keep this manual within reach while operating the product/s all the time!  

As a Lambda Labs products rental partner, always attach the appropriate user manuals to the 
devices. Should 

you need additional printed manuals, please order them from Lambda Labs or 

download a latest version! 

  

• When reselling the product/s, hand over the manual to the new owner and provide written 

documentation about any changes of the system which may have been applied! 

• Always use the latest manual edition! Check our website regularly for updates! 

While all information in this manual has been prepared to the best knowledge and with the utmost care, Lambda Labs can not 
guarantee the accuracy of the documentation in all cases. Lambda Labs disclaims any liability for any errors or omissions that 
may  be  inferred  from  this  manual  or  the  products  described  therein.  This  does  not  apply  to  intent  and  gross  negligence. 
Technical specifications, as well as dimensions, weight and properties do not constitute guaranteed characteristics. Lambda 
Labs expressly reserves the right to make changes and modifications in accordance with statutory provisions and to improve 
product features.  

1.1.

 

Declaration

 

of

 

Symbols

 

and

 

Illustrations

 

of

 

this

 

Manual

 

In

 

order

 

to

 

point

 

out

 

potential

 

sources

 

of

 

danger

 

and

 

application

 

errors,

 

the

 

following

 

symbols

 

and

 

illustrations

 

are

 

used

 

in

 

this

 

manual:

 

www.lambda-labs.com 

!

3

DANGER:

 

The

 

warning

 

symbol

 

"DANGER"

 

indicates

 

that

 

non-observance

 

may

 

pose

 

a

 

danger

 

to

 

the

 

operator

 

or

 

to

 

other

 

persons

 

in

 

close

 

range

 

and

 

the

 

Amplifier

 

Rack

 

product!

DANGER!

 

RISK

 

OF

 

ELECTRIC

 

SHOCK:

 

The warning symbol "RISK OF ELECTRIC SHOCK“ indicates that terminals carry electrical 
voltage of sufficient magnitude to constitute risk of electric shock! 

!

DANGER!

!

Risk of Electric Shock

Summary of Contents for KW-18

Page 1: ...W 18 Amplifier Rack Manual Version 1 1 KW 18 Amplifier Rack Manual Version 1 1 08 2020 2020 Lambda Labs All rights reserved This manual is optimized to save paper and to print 2 pages per DIN A4 sheet...

Page 2: ...onents 11 4 Power Distribution Detailed Description 14 4 1 Power Distribution Detailed Description Front View 14 4 2 Power Distribution Detailed Description Rear View 15 4 3 Power Distribution Cable L...

Page 3: ...Lambda Labs Professional Acoustics KW 18 Amplifier Rack Manual NOTES www lambda labs com 2...

Page 4: ...repared to the best knowledge and with the utmost care Lambda Labs can not guarantee the accuracy of the documentation in all cases Lambda Labs disclaims any liability for any errors or omissions that...

Page 5: ...amage in the equipment and risk of electric shock Use only attachments accessories specified by the manufacturer No user serviceable parts inside Do not remove the top cover or the rear section of the...

Page 6: ...d not be connected or disconnected under load or live Setup environment Keep the device dry and avoid the contact to heavy dust salt sand and prolonged exposure to intense sunlight or strong vibration...

Page 7: ...repair or exchange parts by yourself and without support of a qualified service personnel Manual Keep this manual within easy reach for operating the product s all the time As a Lambda Labs products...

Page 8: ...the unit PE impedance should be always kept low The use of a GFCI unit is recommended In the case of single phase power line application use a common single phase GFCI In the case of three phase power...

Page 9: ...sets Reference Guide The main features of the KW 18 Amplifier Rack 19 10 RU shock mount amplifier rack 4 pieces of braked 100mm heavy duty wheels 4 pieces of handles 2 slidable doors with internal par...

Page 10: ...Labs KW 18 Amplifier Racks on top of each other NOTE Do not stack more than 3 Lambda Labs KW 18 Amplifier Racks _ c Handle To carry and move the rack two spring loaded Handles can be found on both si...

Page 11: ...y up www lambda labs com 10 Danger Do not stack more than 3 Lambda Labs KW 18 Amplifier Racks on top of each other Always brake the wheels of all KW 18 Amplifier Racks when stacking them Danger The Ha...

Page 12: ...eat the steps for the rear door Never operate the amplifiers with closed doors 3 3 Introducing KW 18 Amplifier Rack Internal Components 3 3 Figure 1 KW 18 Amplifier Rack Front Overview Delivery State...

Page 13: ...he KW 18 units _ d Signal Distribution Front Side The 19 2 RU Signal Distribution provides 8 pole 4 pole and 2 pole Speakon Outputs Additionally it provides Dante AES Analogue Inputs and Ethernet Remo...

Page 14: ...ifiers or 3rd party amplifiers with daisy chain outputs Cables are not depicted in the illustrations All cables are labeled Chapter 5 c Power Distribution Rear Side The 19 2 RU Power Distribution prov...

Page 15: ...se always rack screws equipped with plastic washer to avoid damage of the KW 18 surface Caution Never operate the amplifiers with closed doors Both doors need to be open while operating the amplifiers...

Page 16: ...4 3 Chapter 6 c Auxiliary 230V 2 x 6A Socket AUX Power outlets for Auxiliary devices Ethernet Switch DSP etc Chapter 4 1 4 3 Chapter 6 d L1 L2 L3 POWER INDICATOR LAMP Indicators for voltage present o...

Page 17: ...d Pinout please refer to Chapter 8 Chapter 5 2 5 3 Chapter 6 Chapter 8 d AMP 1 OUT 2 4 pin Neutrik Speakon output from Amplifier 1 Channel 2 Top Amplifier Unit For detailed Pinout please refer to Chap...

Page 18: ...6 Chapter 8 k SIGNAL INPUT Analogue or AES EBU Signal input for the Amplifier Rack For detailed Pinout please refer to Chapter 8 Chapter 5 2 5 3 Chapter 6 Chapter 8 l SIGNAL OUTPUT Daisy Chain Analog...

Page 19: ...Chain Ethernet Output Connector 1000MB S for connecting additional Amplifier Rack s _ e AmpRack Analogue AES Inputs Input Audio A Chapter 5 1 5 3 Chapter 6 8 f AmpRack Analogue AES Inputs Input Audio...

Page 20: ...lifier 2 Channel 1 Channel 5 Channel 2 Channel 6 Channel 3 Channel 7 Channel 4 Channel 8 Amplifier Rack Analogue AES Inputs Amplifier Rack Dante Ethernet IO Input Channel A Dante Primary Input Channel...

Page 21: ...ctors MultiLink Breakout Cable 5m 5m shielded 4 pair AES compatible cable with one female 12 pin IP68 WEIPU Connector and 4 pieces of Neutrik Gold Plated XLR female Connectors MultiLink Coupler 0 15m...

Page 22: ...onnectors 8 Pole Speakon Cable 0 7m 0 7m 8 x 4mm2 High Quality Speaker Cable with 2 pieces of Neutrik NLT8FX BAG Connectors 8 Pole 2x4 pole Sub Speakon Breakout Cable 5m 4 pieces of 2 x 2mm2 5m cables...

Page 23: ...ger Risk of Electric Shock Clean the Amplifier Rack with unplugged Power and Signal cables ONLY Caution For cleaning use a soft slightly wet cloth eventually with a bit of Dishwasher Do not use excess...

Page 24: ...nal Acoustics KW 18 Amplifier Rack Manual 8 Appendix 8 1 12 Pole MultiLink WEIPU Pinout www lambda labs com 23 Function PIN Number CH1 1 CH1 2 CH2 3 CH1 GND 4 CH2 5 CH3 6 CH2 GND 7 CH3 GND 8 CH4 GND 9...

Page 25: ...s KW 18 Amplifier Rack Manual 8 2 8 Pole Neutrik NLT8MX BAG Pinout 8 3 4 Pole Neutrik NL4FC Pinout www lambda labs com 24 Function PIN Number CH1 1 CH1 1 CH2 2 CH2 2 CH3 3 CH3 3 CH4 4 CH4 4 Function P...

Page 26: ...Lambda Labs Professional Acoustics KW 18 Amplifier Rack Manual 9 Dimensions www lambda labs com 25 Dimensions mm Weight 79 kg 174 2 lbs 710 565 560 690 560...

Reviews: