Front Panel Interface
39
Lake LM Series Operation Manual Rev 1.3.5
GPO Configuration
To adjust GPO 1 or GPO 2, press the associated button to display a screen similar to that shown in Figure
6-24
Figure 6-24: GPO Configuration
Table 6-4 lists the options available for General Purpose Output (GPO).
Acting on
State when Closed
Protective Mute State
1. Muted
2. Unmuted
Standby State
1. Standby
2. On
Fault
1. No Fault
2. Any Fault
Ready
1. Ready
2. Not Ready
No Indication
-
Table 6-4: GPO Options
Factory Reset and Soft Reset clear the protective
mute state.
Two input options (GPI) and two output options (GPO) may be set at any one time. The default GPIO con-
figuration is shown in Table 6-5. The current state (open/closed) is reported for all GPIO settings on the front
panel and in the Lake Controller software.