22
Front Panel Interface
Lake LM Series Operation Manual Rev 1.3.5
A pink LED indicates a partial mute caused by a mute on an Input Router used by the associated Input
Mixer. If all Input Routers used by an Input Mixer are muted the LED turns red to indicate a full mute; this
type of mute cannot be unmuted from Home View. Input router mutes are accessed via the I/O Status View
as described below, or via the Lake Controller Levels screen as described in the Lake Controller Operation
Manual.
Figure 6-5: Mute Button LED Colours and States
In I/O Status View (accessed via the METER button as described in section 6.9.3) the front panel mute
buttons and meters change to show Input Router mutes and Input Router metering; the dynamic I/O divider
line is not present and the buttons and meters change to represent the input router mute status and associ-
ated metering.
The number of Input Routers varies depending on the whether the frame is configured as Contour or Mesa
as shown in Figure 6-6; the number and location of the Input Router channels is identified by the labels
R1-R8.
Figure 6-6: I/O Status View - Input Router Mutes and Meters
The Input Router Mutes can also be viewed and changed via buttons adjacent to each label the front panel
I/O Status view.
6.8.1 Module Input and Output Mutes
In Home View, dedicated mute buttons are provided for the Module inputs and Module outputs. To mute
or unmute a module input or output, tap the corresponding button. The button illuminates as described in
section 6.8 and shown in Figure 6-5.