9
jumper. If required, the jumper may be set to
“GND” position (see page
6:
“The earth/grounding concept" and page 14: “Jumper settings”).
THE POWER SUPPLY
Mains is connected via a three-pin IEC/CEE socket and a matching
three-wire mains cable with Schuko-type mains connector.
The unit is factory-set to a mains voltage of 230 VAC. Mains voltage
may vary between 190 and 240 V respectively 80 and 120 V without any
effect on flawless operation. The built-in toroidal mains transformer
provides the internal supply voltages of +/- 30 Volt.
THE MAINS FUSE
The internal 0,25 AT fuse is soldered in place on the PCB.
IMPORTANT !!
FOLLOW THE SAFETY INSTRUCTIONS:
A blown fuse may indicate internal problems and should be replaced
during qualified servicing work only !!
THE INPUTS
The signal inputs on the rear are equipped with XLR female-type
sockets, allowing balanced signal injection. They are marked "LEFT"
and "RIGHT" resp.
Balanced Signals XLR Input Wiring:
PIN 1
GND
PIN 2
(+) PHASE
PIN 3
(-) PHASE
For unbalanced signals, two Cinch connectors with integrated break
contacts are provided.
A Cinch plug applied to these sockets will automatically switch off the
balanced input circuitry, thus giving priority the the unbalanced inputs !!