Parameter Name
R/W
Description
Input Data
InternetGatewayDevice.Laird.LORASettings.STPortDown
R/W
This is the port used by the
Semtech packet forwarder
A 2-4 digit port number.
InternetGatewayDevice.Laird.LORASettings.STKeepAlive
R/W
This is the keep alive timeout
used by the Semtech packet
forwarder.
A value in milliseconds
InternetGatewayDevice.Laird.LORASettings.STPushTimeout
R/W
This is the push timeout used by
the Semtech packet forwarder.
A value in milliseconds
InternetGatewayDevice.Laird.LORASettings.STStatInterval
R/W
This is the stat interval used by
the Semtech packet forwarder.
A value in milliseconds
InternetGatewayDevice.Laird.LORASettings.STForwardCRCValid
R/W
This determines if packets with
CRC errors are forwarded.
true, false
InternetGatewayDevice.Laird.LORASettings.STForwardCRCError
R/W
This determines if packets with
CRC errors are forwarded.
true, false
InternetGatewayDevice.Laird.LORASettings.STForwardCRCDisabled R/W
This determines if packets with
CRC errors are forwarded.
true, false
InternetGatewayDevice.Laird.LORASettings.SBSCUPSBootURL
R/W
This is the CUPS-Boot URL used
by Basic Station.
A string representing the URL
of the CUPS-Boot server.
InternetGatewayDevice.Laird.LORASettings.SBSCUPSURL
R/W
This is the CUPS URL used by
Basic Station.
A string representing the URL
of the CUPS server.
InternetGatewayDevice.Laird.LORASettings.SBSLNSURL
R/W
This is the URL to the LNS server
used by Basic Station.
A string representing the URL
of the LNS server.
InternetGatewayDevice.Laird.LORASettings.SBSStatus
R
This is the status of the
connection to the LNS server. 0 -
Disconnected, 1 - Connected.
N/A
InternetGatewayDevice.Laird.LORASettings.RadioConfig
R
This is the radio settings including
channel plan used by the Legacy
Semtech UDP packet forwarder.
N/A
– This can be updated via
vendor config file upload.
Table 6: InternetGatewayDevice.Laird.LANSettings
Parameter Name
R/W
Description
Input
Data
InternetGatewayDevice.Laird.LANSettings
O
This node contains the LAN settings. These are not
writeable as parameters
N/A
InternetGatewayDevice.Laird.LANSettings.IPv4
O
IPv4 settings
N/A
InternetGatewayDevice.Laird.LANSettings.IPv4.DNSServer1
R
The first DNS server
N/A
InternetGatewayDevice.Laird.LANSettings.IPv4.DNSServer2
R
The second DNS server
N/A
InternetGatewayDevice.Laird.LANSettings.IPv4.DeviceAddr
R
Gateway IP address
N/A
InternetGatewayDevice.Laird.LANSettings.IPv4.NetMask
R
The netmask
N/A
InternetGatewayDevice.Laird.LANSettings.IPv4.Broadcast
R
The broadcast IP address
N/A
InternetGatewayDevice.Laird.LANSettings.IPv4.ExtGWIP
R
Gateway IP address (not necessarily external)
N/A
InternetGatewayDevice.Laird.LANSettings.IPv4.IPMethod
R
IP mode (DHCP or static)
N/A
InternetGatewayDevice.Laird.LANSettings.IPv6
O
IPv6 settings
N/A
InternetGatewayDevice.Laird.LANSettings.IPv6.DeviceAddr
R
IPv6 address
N/A
InternetGatewayDevice.Laird.LANSettings.IPv6.Mask
R
IPv6 net mask
N/A
InternetGatewayDevice.Laird.LANSettings.IPv6.IPMethod
R
IPv6 mode
N/A
InternetGatewayDevice.Laird.LANSettings.IPv6.AutoDHCPMethod
R
IPv6 auto DHCP mode
N/A