Page 34
PRIZE SHUTE
FUSE INFORMATION
MAIN AC SUPPLY FUSE (1 x 6 AMP FAST BLOW, M205 TYPE)
This fuse is for the main AC supply and is situated in the IEC mains input socket.
MCU POWER FUSE (1 x 1.5 AMP FAST BLOW, M205 TYPE)
This fuse is for the power supply to the MCU PCB.
MCU CONTROL FUSES (2 x 5 AMP FAST BLOW, M205 TYPE)
These fuses are for the DC transistor drivers on the MCU PCB
3 LED PLAYFIELD DISPLAY CONTROLLER FUSES
(3 x 2.5 AMP FAST BLOW, M205 TYPE)
This fuse is for the +5VDC on the three LED Playfield Display PCBs
DOWN LIGHT FUSES (2 x 5 AMP FAST BLOW, 3AG TYPE)
This fuse is for the two 12VAC 20W Down Light Lamps
FUSE LOCATION DIAGRAM
As viewed from rear
* WARNING! *
Always turn OFF Mains power and unplugged the game, before replacing any fuses.
* NOTE! *
The power cord must be removed before the fuse can be accessed.
* CAUTION! *
Do Not use any fuse that does not meet the specified rating.
MCU Control
Fuses
5A QB M205
LED Controller
Fuses
2.5A QB M205
MCU Power
Fuse
1.5A QB M205
Down Light
Fuses
5A QB 3AG
Main AC Supply
Fuse
6A QB M205
Summary of Contents for Stacker Vendor
Page 52: ...Operator s Manual Stacker Vendor LAI GAMES Page 47 3D PARTS EXPLODE...
Page 53: ...Operator s Manual Stacker Vendor LAI GAMES Page 48...
Page 54: ...Operator s Manual Stacker Vendor LAI GAMES Page 49...
Page 55: ...Operator s Manual Stacker Vendor LAI GAMES Page 50...
Page 56: ...Operator s Manual Stacker Vendor LAI GAMES Page 51...
Page 57: ...Operator s Manual Stacker Vendor LAI GAMES Page 52...
Page 58: ...Operator s Manual Stacker Vendor LAI GAMES Page 53 Stacker Vendor MAIN WIRING DIAGRAM...
Page 59: ...Operator s Manual Stacker Vendor LAI GAMES Page 54 Stacker Vendor POWER WIRING DIAGRAM...
Page 60: ...Operator s Manual Stacker Vendor LAI GAMES Page 55 Stacker Vendor OPTIONAL WIRING DIAGRAM...