Main power cable
Water pump socket
Coolant pipe 90 Deg pipe fitting
12
Electrical Connections for the Machine
There are two electrical cables. One is the main
power cable and has no plug fitted as it will be
dependant on your installation. Ensure that when
installing the electrical supply to the machine that
220v single phase is supplied.
Note:
When wiring the machine to your electrical
system, keep your cable as short as possible. The
cable should not be allowed to run along the floor
as this will cause a trip hazard.
The second cable has a female electrical socket
for connection to the water pump.
Note: A qualified electrician must carry out the
electrical installation.
Fitting the Vacuum Pump
The machine is provided with a 2 inch hose for connection to your vacuum pump.
The hose connects to the vacuum manifold located under the table at the end of
the Swift Vacuum were the vacuum switches are located. When connecting the
hose ensure that it is fitted tightly as you do not want to loose vacuum due to
poor connection. The other end of the hose fits onto the vacuum pump.
Connecting the Water Pipes to the Pump
There are two water pipes that come out
of the caterpillar track. These are used to
provide cooling for the liquid-cooled router
spindle.
Note: Never run the spindle without the
cooling being connected or the spindle
could be damaged.
NEVER handle pump in water with power on, always disconnect pow
er
before handling.
Summary of Contents for Laguna Series