Electrical Equipment:
According to European Standard “CENELEC EN 60 204-1” which simulates modification,
publication (IED 204-1)
•
The electrical equipment ensures protection against electric shock as result of direct or
indirect contact. The active parts of this equipment are housed in a box so that access is
limited by screws can only be removed with a special tool; the parts are fed with
alternating current at low voltage (24V).
•
This equipment is protected against splashes of water and dust.
•
Protection of the system against short circuits is ensures by means of rapid fuses and
earthing; in the event of motor overload, protection is provided by thermal probe.
•
In the event of incorrect operation or of dangerous conditions, the machine may be
stopped immediately by pressing the red emergency stop button.
•
In the event of a power cut, the specific start-up button must be reset.
•
This machine has been tested in conformity with point 20 of EN 60204.
SET UP
TRANSPORTING AND ANCHORING
Position the machine on a firm cement floor, keeping a minimum distance from 2-1/2 feet from
any wall. Anchor it to the ground using screws and expansion plugs or tie rods sunk in the
cement, ensure it is sitting level before anchoring.
ELECTRICAL CONNECTION
The machine is not provided with an electrical plug, so the customer must find a suitable one for
working conditions.
Three-Phase machine wiring diagram below:
Single-Phase machine wiring diagram below: