background image

 

 

Dake Corporation 

 

 

1809 Industrial Park Dr 

 

Grand Haven, MI 49417 

www.dakecorp.com

 

 

 

961005 

  2 

REV042023 

 

 

DAKE STANDARD LIMITED WARRANTY 

 

Finished Machines 

  Dake warrants to the original purchaser the finished machine manufactured or distributed 

by it to be free from defects in material and workmanship under normal use and service 

within 1 year (12 months) from the delivery date to the end user. 

 

Parts 

  Dake warrants to the original purchaser the component part manufactured or distributed 

by it to be free from defects in material and workmanship under normal use and service 

within 30 days from the delivery date to the end user. 

The standard limited warranty includes the replacement of the defective component part 

at no cost to the end user.  

 

Sale of Service (Repairs)

 

  Dake warrants to the original purchaser the component part repaired by Dake 

Corporation at the manufacturing facility to be free from defects in material and 

workmanship under normal use and service within 90 days from the return date to the 

end user, as it pertains to the repair work completed. The standard limited warranty 

includes repair of the defective component part, at no cost to the end user. 

 

Warranty Process  

  Subject to the conditions hereinafter set forth, the manufacturer will repair or replace any 

portion of the product that proves defective in materials or workmanship. The 

manufacturer retains the sole right and option, after inspection, to determine whether to 

repair or replace defective equipment, parts or components. The manufacturer will 

assume ownership of any defective parts replaced under this warranty.   

  All requested warranty claims must be communicated to the distributor or representative 

responsible for the sale. Once communication has been initiated, Dake Customer Service 

must be contacted for approval: 

  Phone: (800) 937-3253 

  Email: 

[email protected]

 

 

  When contacting Dake, please have the following information readily available: 

  

- Model # 

  

- Serial # 

  

- Sales Order #  

 

  Purchasers who notify Dake within the warranty period will be issued a Case number 

and/or a Return Material Authorization (RMA) number. If the item is to be returned per 

Dake’s request, the RMA number must be clearly written on the exterior packaging. Any 

item shipped to Dake without an RMA will not be processed.  

 

 

Summary of Contents for Dake SG-75

Page 1: ...rk Dr Fax 800 846 3253 Grand Haven MI 49417 DAKE STANDING METAL BELT SANDER Model SG 75 INSTRUCTIONAL MANUAL WARNING Read and understand all instructions and responsibilities before operating Failure...

Page 2: ...TERMS CONDITIONS OF SALE 5 SPECIFICATIONS 6 SAFETY 6 SET UP 8 PLACEMENT 8 ELECTRICAL 9 INSTALLING CHANGING BELT 10 CHECKING ADJUSTING BELT TRACKING 10 FIRST TIME OPERATION 11 CORRECTING PHASE POLARITY...

Page 3: ...o the repair work completed The standard limited warranty includes repair of the defective component part at no cost to the end user Warranty Process Subject to the conditions hereinafter set forth th...

Page 4: ...stallation or failure to operate or maintain the unit in accordance with the printed instructions provided c Defects or malfunctions resulting from abuse accident neglect or damage outside of prepaid...

Page 5: ...ved by Customer Service a representative will supply a Return Material Authorization RMA number The returned item must have the provided RMA number clearly marked on the outside packaging Any item rec...

Page 6: ...ry may become invalid sixty 60 days after date of quotation Unless otherwise specified in Dake s quotation installation services and final on site adjustments are not included in the quotation TAXES P...

Page 7: ...5HP Voltage 220V Single Phase Amps 3 9A Belt Included 80 Grit 3 x 79 Belt Speed 5018 FPM Base 16 x 13 Height 42 Weight 117 lbs In the space provided record the serial number and model number of the m...

Page 8: ...pping and losing control or accidentally contacting cutting tool or moving parts Dust created by machinery operations may cause cancer birth defects eye damage raspatory issues or long term respirator...

Page 9: ...l laws and legislation for anchoring machinery Anchoring machine to the floor prevents tipping or shifting and reduces vibration that may occur during operation resulting in a machine that runs quiete...

Page 10: ...ecified circuit requirements Circuit requirements in this manual apply to a dedicated circuit where only one machine will be running on the circuit at a time If machine will be connected to a shared c...

Page 11: ...al CHECKING ADJUSTING BELT TRACKING 1 Make sure machine is not connected to power source 2 Use key to unlock and open belt access door 3 Standing in front of machine rotate either wheel by hand so the...

Page 12: ...o CORRECTING PHASE POLARITY section of this manual 3 Ensure motor runs smoothly then activate the E Stop to ensure E Stop is working properly a When E Stop is activated the cover will shut if the cove...

Page 13: ...rrous metals Zirconia Alumina Finishing wet or dry grinding Ferrous metals some steels Ceramic Aggressing grinding deburring Heat sensitive metals Silicon Carbide Cutting stock removal wet or dry grin...

Page 14: ...or wiring connections 4 Test for good contacts correct wiring 5 Clean replace belt reduce feed rate grinding depth 6 Clean motor let cool and reduce workload 7 Move machine closer to power supply use...

Page 15: ...Contact wheel damaged 1 Clean belt and reduce workpiece pressure 2 Keep workpiece moving when grinding 3 Use a finer belt grit 4 Replace contact wheel Snake shaped marks on workpiece 1 Belt loaded up...

Page 16: ...Dake Corporation 1809 Industrial Park Dr Grand Haven MI 49417 www dakecorp com 961005 15 REV042023 ELECTRICAL DIAGRAM Motor junction box Push button magnetic switch...

Page 17: ...Dake Corporation 1809 Industrial Park Dr Grand Haven MI 49417 www dakecorp com 961005 16 REV042023 EXPLODED PARTS VIEW...

Page 18: ...8 Guide Bolt M10 1 5x27mm 42 4 Tap Screw M4 2x19 19 Hex Standoff Male Female M20 1 5x5mm M10 1 5 42 5 Magnet Switch w E Stop Cover 20 Motor 1 1 2HP 220V 3 Phase 42 6 Strain Relief Type 3 M18 1 5 20 1...

Reviews: