Problem

Possible Cause / Solution

Startup

Maintenance

A) Fogger will not draw chemical or is sputtering
B) Fog is too wet
C) Doesn't come on when switch is turned on.
D) Comes on and runs continuously.

1, 2, 3, 4
1, 5
6, 7
6

8, 9, 10, 11

Possible Cause / Solution

Startup

Maintenance

1.  Air line too small, not enough air pressure or volume

See REQUIREMENTS, page 1.

2.  Air pressure too high.

Slightly close the air supply valve to lower the pressure
by lowering the volume until the fogger smooths out.

3.  Fogger too high to draw chemical, 12' maximum

Raise the level of the chemical

4.  Chemical tube kinked or not immersed in chemical or

chemical depleted.

Straighten tube / replenish chemical

5.  Drawing too much solution

Order and install optional metering tip or needle valve (4
& 8 Way only).

6.  Timer failed

Replace timer.

7.  May have electrical problems

Ensure circuit breaker (5 Amp) has not been tripped.
Have a qualified electrician check electrical connections.

8.  Pin hole or cut in suction tube

Replace suction tube.

9.  Chemical strainer clogged up

Clean or replace

10.  Metering tip or metering tip holder clogged

Clean or replace metering tip and/or metering tip holder.

11.  Debris clogging the fogger inlet jets

Disconnect air supply, remove fogger bodies and
visually inspect; remove debris from fogger inlet.

PREVENTIVE MAINTENANCE: When the unit will be out of service for extended periods, place chemical tube(s) in water and flush the chemical out