22/38
Instructions manual Nitrogen Compact Booster
Operation
6.4
Operating the machine
NOTICE
Damage to the machine
If the controls are set incorrectly, parts of the machine may be damaged.
Prior to opening of the nitrogen bottle the drive air pressure has to be adjusted and the valve
at the bottle pressure regulator has to be closed.
Over pressure can occur in the machine if the drive air pressure is too high.
If the valve is open then a pin in the bottle pressure regulator can be damaged.
The following description is applicable to the operation with all required parts and all possible
additional equipment.
6.4.1
Settings prior to the operation
1. Drive air pressure has to be set.
a) Turning knob (a) at the filter and control valve has to be pulled up.
b) By turning the knob, set the air pressure to a maximum of 6 bar (right = pressure in-
crease, left = pressure reduction)
c) Turning knob (a) at the filter and control valve has to be pushed down.
2. Close the valve of the bottle pressure regulator.
a) Turn turning knob (b) at the bottle pressure regulator until it arrests.
Fig. 6-1 Settings prior to the operation
1.
2.
a
b